EK-K-s-463BE10-B13 C
73.16 kW
Defrost: None
Product code: EK-K-b-463BE10-B31 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 67,829 m³/h |
|---|---|
| External surface | 219.7 m² |
| Inner volume | 95.2 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 564 kg |
| Quantity | 4 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 10,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 70.0 dB(A) |
|---|---|
| Sound power | 93.1 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø54 |
| EK-K-b-463BE10-B31 C | None |
|---|---|
| EK-K-b-463BE10-B31 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 31.82 | 30.61 | 29.79 | 29.24 | 28.68 | 28.15 | 27.65 | 27.57 | 29.09 | 31.30 | 30.36 | 30.01 | 29.54 | 28.84 |
| 5 | 38.27 | 37.17 | 36.40 | 39.83 | 39.11 | 38.34 | 37.58 | 37.42 | 39.51 | 42.45 | 41.03 | 40.51 | 39.77 | 38.68 |
| 6 | 48.25 | 47.36 | 46.74 | 51.37 | 50.63 | 49.73 | 48.76 | 48.42 | 51.08 | 54.84 | 52.88 | 52.18 | 51.19 | 49.71 |
| 7 | 58.04 | 57.60 | 57.35 | 63.52 | 62.90 | 61.98 | 60.90 | 60.44 | 63.75 | 68.42 | 65.86 | 64.92 | 63.59 | 61.56 |
| 8 | 67.51 | 67.74 | 68.02 | 75.87 | 75.56 | 74.81 | 73.67 | 73.16 | 77.15 | 82.88 | 79.77 | 78.61 | 76.91 | 74.28 |
| 9 | 84.90 | 85.85 | 87.05 | 88.01 | 88.18 | 87.74 | 86.83 | 86.36 | 91.15 | 98.05 | 94.47 | 93.07 | 91.04 | 87.82 |
| 10 | 93.29 | 95.27 | 97.23 | 99.09 | 100.14 | 100.57 | 100.20 | 99.87 | 105.49 | 113.64 | 109.71 | 108.14 | 105.83 | 102.10 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 27.58 | 26.58 | 25.94 | 25.55 | 25.15 | 24.77 | 24.39 | 24.61 | 26.00 | 28.04 | 27.29 | 27.02 | 26.64 | 26.08 |
| 5 | 32.90 | 31.91 | 31.27 | 34.27 | 33.73 | 33.15 | 32.56 | 32.69 | 34.61 | 37.29 | 36.20 | 35.83 | 35.31 | 34.48 |
| 6 | 41.23 | 40.33 | 39.75 | 43.74 | 43.13 | 42.42 | 41.63 | 41.61 | 43.98 | 47.33 | 45.74 | 45.19 | 44.43 | 43.30 |
| 7 | 49.73 | 49.03 | 48.61 | 53.68 | 53.12 | 52.35 | 51.42 | 51.26 | 54.12 | 58.19 | 56.09 | 55.33 | 54.25 | 52.62 |
| 8 | 57.98 | 57.66 | 57.57 | 63.97 | 63.54 | 62.75 | 61.75 | 61.48 | 64.88 | 69.76 | 67.14 | 66.16 | 64.75 | 62.56 |
| 9 | 73.30 | 73.55 | 73.93 | 74.32 | 74.14 | 73.50 | 72.49 | 72.13 | 76.12 | 81.90 | 78.80 | 77.56 | 75.82 | 73.05 |
| 10 | 81.82 | 82.80 | 83.58 | 84.50 | 84.68 | 84.27 | 83.38 | 83.03 | 87.65 | 94.32 | 90.85 | 89.46 | 87.42 | 84.13 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 109.713 | 90.854 |
| SC2 | 0 | 8 | 73.156 | 61.478 |
| SC3 | -18 | 7 | 63.313 | 53.489 |
| SC4 | -25 | 6 | 46.735 | 39.749 |
| SC5 | -34 | 6 | 48.121 | 41.087 |
| A | 2460 mm |
|---|---|
| B | 1190 mm |
| C | 1935 mm |
| F | 990 mm |
| G | 2035 mm |
| E | 2050 mm |
| G1 | 1035 mm |
| G2 | 1000 mm |
| D IN | 2 x Ø42 |
| D OUT | 2 x Ø54 |
| Length | 2460 mm |
|---|---|
| Width | 1190 mm |
| Height | 2050 mm |
Our engineers answer with a selection for your conditions.