EK-S-263BE10-B08 C
39.45 kW
Defrost: None
Product code: EK-S-350AG10-B10 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 22,078 m³/h |
|---|---|
| External surface | 175.8 m² |
| Inner volume | 73.3 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 516 kg |
| Quantity | 3 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,360 rpm |
| Power | 2,070 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 85.1 dB(A) |
| Energy class | C |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EK-S-350AG10-B10 C | None |
|---|---|
| EK-S-350AG10-B10 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 18.12 | 17.59 | 17.28 | 17.12 | 16.94 | 16.75 | 16.55 | 16.66 | 17.67 | 19.10 | 18.63 | 18.47 | 18.22 | 17.84 |
| 5 | 21.16 | 20.67 | 20.39 | 22.50 | 22.27 | 22.01 | 21.72 | 21.77 | 23.04 | 24.87 | 24.16 | 23.91 | 23.56 | 23.04 |
| 6 | 26.08 | 25.67 | 25.45 | 28.18 | 27.96 | 27.66 | 27.30 | 27.27 | 28.83 | 31.08 | 30.11 | 29.75 | 29.24 | 28.47 |
| 7 | 31.06 | 30.77 | 30.63 | 34.05 | 33.88 | 33.59 | 33.18 | 33.09 | 34.97 | 37.68 | 36.44 | 35.97 | 35.29 | 34.23 |
| 8 | 35.87 | 35.80 | 35.89 | 40.05 | 39.98 | 39.70 | 39.29 | 39.16 | 41.37 | 44.59 | 43.08 | 42.50 | 41.64 | 40.28 |
| 9 | 45.02 | 45.28 | 45.65 | 46.06 | 46.14 | 45.94 | 45.55 | 45.41 | 47.97 | 51.69 | 49.98 | 49.28 | 48.26 | 46.60 |
| 10 | 49.97 | 50.65 | 51.36 | 52.06 | 52.21 | 52.16 | 51.84 | 51.75 | 54.69 | 58.93 | 57.03 | 56.24 | 55.07 | 53.14 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 15.84 | 15.38 | 15.14 | 15.03 | 14.90 | 14.76 | 14.61 | 14.76 | 15.68 | 16.97 | 16.59 | 16.46 | 16.28 | 16.01 |
| 5 | 18.40 | 17.95 | 17.71 | 19.56 | 19.39 | 19.19 | 18.96 | 19.06 | 20.20 | 21.83 | 21.23 | 21.02 | 20.73 | 20.30 |
| 6 | 22.62 | 22.19 | 21.98 | 24.33 | 24.15 | 23.91 | 23.62 | 23.65 | 25.02 | 27.01 | 26.19 | 25.89 | 25.46 | 24.80 |
| 7 | 26.84 | 26.49 | 26.35 | 29.26 | 29.11 | 28.86 | 28.51 | 28.48 | 30.11 | 32.48 | 31.42 | 31.03 | 30.45 | 29.54 |
| 8 | 31.10 | 30.86 | 30.82 | 34.29 | 34.20 | 33.96 | 33.59 | 33.51 | 35.41 | 38.17 | 36.90 | 36.40 | 35.67 | 34.50 |
| 9 | 39.11 | 39.05 | 39.18 | 39.41 | 39.35 | 39.15 | 38.78 | 38.69 | 40.87 | 44.04 | 42.58 | 41.98 | 41.10 | 39.66 |
| 10 | 43.52 | 43.74 | 44.09 | 44.51 | 44.58 | 44.44 | 44.06 | 43.98 | 46.46 | 50.05 | 48.42 | 47.72 | 46.70 | 45.00 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 57.034 | 48.417 |
| SC2 | 0 | 8 | 39.158 | 33.507 |
| SC3 | -18 | 7 | 33.999 | 29.213 |
| SC4 | -25 | 6 | 25.451 | 21.975 |
| SC5 | -34 | 6 | 26.019 | 22.545 |
| A | 2860 mm |
|---|---|
| B | 1100 mm |
| C | 1930 mm |
| F | 700 mm |
| G | 2465 mm |
| E | 2170 mm |
| G1 | 833 mm |
| G2 | 800 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 2860 mm |
|---|---|
| Width | 1100 mm |
| Height | 2170 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.