EK-SR-191DC10-A03 C
28.87 kW
Defrost: None
Product code: EK-SR-180BC4-A05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 24,885 m³/h |
|---|---|
| External surface | 130.3 m² |
| Inner volume | 26.9 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 481 kg |
| Quantity | 1 |
|---|---|
| Diameter | 800 mm |
| Speed | 1,310 rpm |
| Power | 3,900 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 69.0 dB(A) |
|---|---|
| Sound power | 93.0 dB(A) |
| Energy class | E |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø42 |
| EK-SR-180BC4-A05 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 12.01 | 12.00 | 12.00 | 11.99 | 11.93 | 11.83 | 11.72 | 11.75 | 12.42 | 13.39 | 13.04 | 12.91 | 12.72 | 12.45 |
| 5 | 13.87 | 14.13 | 14.32 | 16.07 | 16.08 | 15.99 | 15.80 | 15.81 | 16.74 | 18.05 | 17.54 | 17.36 | 17.10 | 16.69 |
| 6 | 16.67 | 17.22 | 17.73 | 20.19 | 20.40 | 20.42 | 20.30 | 20.33 | 21.52 | 23.22 | 22.53 | 22.28 | 21.91 | 21.35 |
| 7 | 19.01 | 19.88 | 20.65 | 23.69 | 24.17 | 24.44 | 24.55 | 24.76 | 26.28 | 28.49 | 27.86 | 27.62 | 27.16 | 26.43 |
| 8 | 21.18 | 22.41 | ≈ 23.49 | ≈ 27.15 | 27.84 | 28.25 | 28.46 | 28.73 | 30.50 | 33.09 | 32.35 | 32.05 | 31.62 | 30.91 |
| 9 | 25.75 | 27.53 | 29.14 | 30.52 | 31.48 | 32.08 | 32.41 | 32.75 | 34.79 | 37.76 | 36.93 | 36.59 | 36.09 | 35.26 |
| 10 | ≈ 27.75 | 29.99 | 32.03 | 33.80 | 35.05 | 35.89 | 36.37 | 36.81 | 39.12 | 42.49 | 41.59 | 41.21 | 40.64 | 39.69 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 10.81 | 10.71 | 10.69 | 10.70 | 10.65 | 10.58 | 10.49 | 10.57 | 11.19 | 12.09 | 11.80 | 11.69 | 11.54 | 11.31 |
| 5 | 12.48 | 12.59 | 12.69 | 14.20 | 14.18 | 14.08 | 13.96 | 14.02 | 14.85 | 16.04 | 15.61 | 15.46 | 15.25 | 14.93 |
| 6 | 15.14 | 15.52 | 15.76 | 17.79 | 17.89 | 17.86 | 17.74 | 17.79 | 18.84 | 20.33 | 19.74 | 19.53 | 19.23 | 18.77 |
| 7 | 17.44 | 18.07 | 18.64 | 21.28 | 21.63 | 21.81 | 21.75 | 21.82 | 23.10 | 24.95 | 24.22 | 23.95 | 23.54 | 22.91 |
| 8 | 19.50 | 20.42 | 21.24 | 24.39 | 24.90 | 25.20 | 25.33 | 25.54 | 27.11 | 29.40 | 28.72 | 28.46 | 28.07 | 27.35 |
| 9 | 23.79 | 25.16 | 26.39 | 27.45 | 28.16 | 28.59 | 28.81 | 29.07 | 30.86 | 33.48 | 32.71 | 32.40 | 31.94 | 31.19 |
| 10 | 25.74 | 27.50 | 29.08 | 30.45 | 31.39 | 31.98 | 32.31 | 32.63 | 34.65 | 37.61 | 36.77 | 36.42 | 35.90 | 35.02 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 41.587 | 36.773 |
| SC2 | 0 | 8 | 28.729 | 25.539 |
| SC3 | -18 | 7 | 23.911 | 21.437 |
| SC4 | -25 | 6 | 17.726 | 15.758 |
| SC5 | -34 | 6 | 16.808 | 15.248 |
| A | 1760 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 1365 mm |
| H | 1393 mm |
| I | 1790 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø42 |
| Length | 1760 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.