EK-SR-191CG10-A04 C
44.50 kW
Defrost: None
Product code: EK-SR-191DE7-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 29,372 m³/h |
|---|---|
| External surface | 197.7 m² |
| Inner volume | 63.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 608 kg |
| Quantity | 1 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 2,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 66.0 dB(A) |
|---|---|
| Sound power | 90.0 dB(A) |
| Energy class | D |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-191DE7-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 19.54 | 19.24 | 19.07 | 18.98 | 18.84 | 18.65 | 18.45 | 18.60 | 19.70 | 21.27 | 20.73 | 20.52 | 20.24 | 19.81 |
| 5 | 22.76 | 22.64 | 22.55 | 25.08 | 24.96 | 24.74 | 24.45 | 24.55 | 26.00 | 28.07 | 27.29 | 27.01 | 26.61 | 26.02 |
| 6 | 27.79 | 27.98 | 28.18 | 31.53 | 31.50 | 31.28 | 30.96 | 31.02 | 32.82 | 35.40 | 34.33 | 33.94 | 33.38 | 32.53 |
| 7 | 32.61 | 33.23 | 33.79 | 38.07 | 38.15 | 38.07 | 37.79 | 37.83 | 40.02 | 43.16 | 41.81 | 41.30 | 40.56 | 39.38 |
| 8 | 37.14 | 38.12 | 39.13 | 44.43 | 44.91 | 45.02 | 44.83 | 44.90 | 47.51 | 51.30 | 49.71 | 49.08 | 48.16 | 46.67 |
| 9 | 45.47 | 47.22 | 48.82 | 50.26 | 51.16 | 51.67 | 51.85 | 52.13 | 55.19 | 59.65 | 57.87 | 57.15 | 56.07 | 54.31 |
| 10 | 49.51 | 51.86 | 53.99 | 55.87 | 57.07 | 57.79 | 58.11 | 58.57 | 62.13 | 67.34 | 65.71 | 65.02 | 63.99 | 62.13 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 16.72 | 16.41 | 16.25 | 16.19 | 16.09 | 15.97 | 15.82 | 16.02 | 17.01 | 18.42 | 18.01 | 17.87 | 17.64 | 17.31 |
| 5 | 19.32 | 19.12 | 19.03 | 21.14 | 21.04 | 20.87 | 20.65 | 20.80 | 22.06 | 23.85 | 23.23 | 23.01 | 22.70 | 22.25 |
| 6 | 23.67 | 23.61 | 23.65 | 26.34 | 26.29 | 26.11 | 25.85 | 25.94 | 27.47 | 29.67 | 28.80 | 28.48 | 28.03 | 27.34 |
| 7 | 27.86 | 28.06 | 28.30 | 31.73 | 31.76 | 31.60 | 31.32 | 31.37 | 33.19 | 35.83 | 34.71 | 34.29 | 33.68 | 32.71 |
| 8 | 31.88 | 32.42 | 32.94 | 37.13 | 37.33 | 37.26 | 36.95 | 36.99 | 39.11 | 42.23 | 40.89 | 40.36 | 39.59 | 38.34 |
| 9 | 39.65 | 40.71 | 41.54 | 42.38 | 42.81 | 42.88 | 42.70 | 42.76 | 45.24 | 48.83 | 47.32 | 46.68 | 45.76 | 44.26 |
| 10 | 43.38 | 44.85 | 46.23 | 47.49 | 48.25 | 48.58 | 48.50 | 48.64 | 51.47 | 55.58 | 53.90 | 53.19 | 52.13 | 50.37 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 65.710 | 53.904 |
| SC2 | 0 | 8 | 44.902 | 36.985 |
| SC3 | -18 | 7 | 38.075 | 31.766 |
| SC4 | -25 | 6 | 28.182 | 23.650 |
| SC5 | -34 | 6 | 27.870 | 23.691 |
| A | 1760 mm |
|---|---|
| B | 1360 mm |
| C | 3390 mm |
| F | 1310 mm |
| G | 2370 mm |
| E | 1365 mm |
| H | 1393 mm |
| I | 1790 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 1760 mm |
|---|---|
| Width | 1393 mm |
| Height | 3390 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.