EK-SR-280CC7-A05 C
53.00 kW
Defrost: None
Product code: EK-SR-191DG7-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 27,628 m³/h |
|---|---|
| External surface | 263.6 m² |
| Inner volume | 82.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 650 kg |
| Quantity | 1 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 2,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 66.0 dB(A) |
|---|---|
| Sound power | 90.0 dB(A) |
| Energy class | C |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-191DG7-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 22.49 | 22.60 | 22.74 | 22.88 | 22.86 | 22.73 | 22.53 | 22.78 | 24.19 | 26.16 | 25.53 | 25.31 | 25.01 | 24.47 |
| 5 | 25.60 | 26.07 | 26.50 | 29.85 | 29.93 | 29.86 | 29.64 | 29.85 | 31.64 | 34.20 | 33.25 | 32.91 | 32.42 | 31.69 |
| 6 | 30.56 | 31.57 | 32.46 | 36.87 | 37.15 | 37.25 | 37.10 | 37.30 | 39.49 | 42.69 | 41.45 | 40.98 | 40.29 | 39.20 |
| 7 | 35.15 | 36.58 | 38.01 | 43.59 | 44.39 | 44.76 | 44.76 | 45.02 | 47.70 | 51.60 | 50.11 | 49.52 | 48.64 | 47.19 |
| 8 | 39.02 | 41.19 | ≈ 43.16 | ≈ 49.86 | 51.15 | 51.93 | 52.30 | 52.83 | 56.05 | 60.70 | 59.03 | 58.33 | 57.29 | 55.51 |
| 9 | 47.34 | 50.46 | 53.31 | 55.80 | 57.53 | 58.59 | 59.17 | 59.84 | 63.54 | 68.96 | 67.39 | 66.71 | 65.65 | 63.83 |
| 10 | ≈ 50.96 | 54.86 | 58.43 | 61.56 | 63.75 | 65.20 | 66.02 | 66.87 | 71.04 | 77.12 | 75.43 | 74.67 | 73.47 | 71.39 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 18.99 | 18.93 | 18.95 | 19.03 | 18.99 | 18.89 | 18.72 | 19.00 | 20.20 | 21.88 | 21.39 | 21.22 | 20.99 | 20.65 |
| 5 | 21.63 | 21.69 | 21.90 | 24.56 | 24.60 | 24.50 | 24.29 | 24.52 | 26.01 | 28.14 | 27.37 | 27.10 | 26.71 | 26.12 |
| 6 | 25.93 | 26.40 | 26.85 | 30.28 | 30.45 | 30.37 | 30.15 | 30.34 | 32.14 | 34.75 | 33.71 | 33.32 | 32.74 | 31.83 |
| 7 | 30.01 | 30.89 | 31.70 | 35.98 | 36.35 | 36.42 | 36.23 | 36.32 | 38.46 | 41.59 | 40.30 | 39.79 | 39.03 | 37.79 |
| 8 | 33.82 | 35.20 | 36.25 | 41.45 | 42.11 | 42.36 | 42.28 | 42.50 | 44.99 | 48.64 | 47.16 | 46.53 | 45.60 | 44.07 |
| 9 | 41.49 | 43.35 | 45.19 | 46.82 | 47.85 | 48.37 | 48.43 | 48.74 | 51.61 | 55.80 | 54.16 | 53.44 | 52.36 | 50.54 |
| 10 | 44.75 | 47.35 | 49.71 | 51.78 | 53.13 | 53.94 | 54.28 | 54.81 | 58.13 | 62.97 | 61.25 | 60.44 | 59.22 | 57.12 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 75.434 | 61.247 |
| SC2 | 0 | 8 | 52.826 | 42.496 |
| SC3 | -18 | 7 | 43.973 | 36.170 |
| SC4 | -25 | 6 | 32.455 | 26.845 |
| SC5 | -34 | 6 | 30.818 | 26.066 |
| A | 1760 mm |
|---|---|
| B | 1360 mm |
| C | 3390 mm |
| F | 1310 mm |
| G | 2370 mm |
| E | 1365 mm |
| H | 1393 mm |
| I | 1790 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 1760 mm |
|---|---|
| Width | 1393 mm |
| Height | 3390 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.