EK-SR-191CG7-A04 C
48.47 kW
Defrost: None
Product code: EK-SR-280AE10-A05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 45,528 m³/h |
|---|---|
| External surface | 142.8 m² |
| Inner volume | 60.1 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 660 kg |
| Quantity | 2 |
|---|---|
| Diameter | 800 mm |
| Speed | 1,310 rpm |
| Power | 7,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 71.0 dB(A) |
|---|---|
| Sound power | 95.1 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-280AE10-A05 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 20.35 | 19.87 | 19.52 | 19.25 | 18.91 | 18.54 | 18.17 | 18.16 | 19.14 | 20.56 | 19.87 | 19.62 | 19.27 | 18.75 |
| 5 | 24.18 | 23.95 | 23.77 | 26.21 | 25.89 | 25.45 | 24.95 | 24.93 | 26.34 | 28.30 | 27.33 | 26.97 | 26.45 | 25.65 |
| 6 | 29.85 | 30.02 | 30.15 | 33.60 | 33.41 | 33.01 | 32.44 | 32.37 | 34.19 | 36.74 | 35.40 | 34.93 | 34.25 | 33.23 |
| 7 | 35.25 | 35.80 | 36.37 | 40.93 | 41.03 | 40.80 | 40.32 | 40.26 | 42.53 | 45.74 | 44.08 | 43.46 | 42.57 | 41.17 |
| 8 | 39.87 | 41.04 | 42.14 | 47.91 | 48.54 | 48.76 | 48.43 | 48.43 | 51.20 | 55.18 | 53.28 | 52.54 | 51.46 | 49.70 |
| 9 | 49.02 | 50.94 | 52.68 | 54.21 | 55.14 | 55.63 | 55.75 | 56.10 | 59.48 | 64.42 | 62.74 | 61.93 | 60.68 | 58.63 |
| 10 | 53.43 | 56.04 | 58.37 | 60.40 | 61.71 | 62.45 | 62.73 | 63.18 | 67.01 | 72.61 | 70.75 | 69.98 | 68.82 | 66.91 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 18.05 | 17.58 | 17.26 | 17.04 | 16.77 | 16.49 | 16.20 | 16.28 | 17.18 | 18.49 | 17.93 | 17.72 | 17.43 | 17.00 |
| 5 | 21.39 | 21.01 | 20.81 | 22.96 | 22.68 | 22.32 | 21.92 | 21.95 | 23.21 | 24.98 | 24.18 | 23.90 | 23.51 | 22.90 |
| 6 | 26.45 | 26.37 | 26.34 | 29.26 | 29.02 | 28.67 | 28.21 | 28.17 | 29.77 | 32.02 | 30.91 | 30.51 | 29.95 | 29.10 |
| 7 | 31.33 | 31.62 | 31.89 | 35.70 | 35.65 | 35.36 | 34.89 | 34.81 | 36.77 | 39.56 | 38.15 | 37.62 | 36.85 | 35.68 |
| 8 | 35.97 | 36.58 | 37.25 | 42.02 | 42.23 | 42.11 | 41.73 | 41.68 | 44.04 | 47.44 | 45.76 | 45.12 | 44.17 | 42.67 |
| 9 | 44.40 | 45.70 | 46.92 | 48.04 | 48.70 | 48.97 | 48.72 | 48.73 | 51.53 | 55.59 | 53.73 | 52.98 | 51.88 | 50.09 |
| 10 | 48.55 | 50.39 | 52.07 | 53.58 | 54.51 | 55.00 | 55.13 | 55.44 | 58.77 | 63.64 | 61.83 | 61.00 | 59.76 | 57.71 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 70.750 | 61.832 |
| SC2 | 0 | 8 | 48.433 | 41.679 |
| SC3 | -18 | 7 | 41.013 | 35.712 |
| SC4 | -25 | 6 | 30.150 | 26.344 |
| SC5 | -34 | 6 | 29.935 | 26.466 |
| A | 3060 mm |
|---|---|
| B | 1360 mm |
| C | 2490 mm |
| F | 1310 mm |
| G | 1470 mm |
| E | 2665 mm |
| H | 1393 mm |
| I | 3090 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 3060 mm |
|---|---|
| Width | 1393 mm |
| Height | 2490 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.