EK-SR-180CG4-A05 C
54.72 kW
Defrost: None
Product code: EK-SR-280BE10-A05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 49,670 m³/h |
|---|---|
| External surface | 190.4 m² |
| Inner volume | 79.7 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 743 kg |
| Quantity | 2 |
|---|---|
| Diameter | 800 mm |
| Speed | 1,310 rpm |
| Power | 7,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 72.0 dB(A) |
|---|---|
| Sound power | 95.9 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-280BE10-A05 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 22.66 | 22.54 | 22.45 | 22.38 | 22.16 | 21.85 | 21.50 | 21.46 | 22.62 | 24.31 | 23.50 | 23.20 | 22.78 | 22.14 |
| 5 | 26.33 | 26.62 | 26.86 | 30.05 | 29.93 | 29.68 | 29.30 | 29.23 | 30.89 | 33.23 | 32.13 | 31.73 | 31.15 | 30.28 |
| 6 | 31.84 | 32.73 | 33.48 | 37.72 | 37.96 | 37.90 | 37.61 | 37.59 | 39.73 | 42.79 | 41.41 | 40.88 | 40.12 | 38.94 |
| 7 | 36.94 | 38.28 | 39.62 | 45.32 | 46.02 | 46.29 | 46.19 | 46.30 | 49.00 | 52.89 | 51.26 | 50.62 | 49.68 | 48.16 |
| 8 | 41.07 | 43.17 | ≈ 45.07 | ≈ 51.93 | 53.16 | 53.91 | 54.28 | 54.75 | 58.11 | 63.03 | 61.42 | 60.70 | 59.63 | 57.85 |
| 9 | 50.00 | 53.10 | 55.90 | 58.35 | 60.06 | 61.14 | 61.74 | 62.36 | 66.22 | 71.88 | 70.27 | 69.61 | 68.60 | 66.92 |
| 10 | 53.98 | 57.91 | 61.47 | 64.60 | 66.83 | 68.31 | 69.19 | 69.99 | 74.37 | 80.77 | 79.07 | 78.34 | 77.22 | 75.33 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 20.19 | 19.97 | 19.83 | 19.74 | 19.55 | 19.30 | 19.02 | 19.08 | 20.16 | 21.71 | 21.05 | 20.80 | 20.45 | 19.93 |
| 5 | 23.48 | 23.54 | 23.61 | 26.28 | 26.17 | 25.94 | 25.60 | 25.61 | 27.09 | 29.18 | 28.27 | 27.94 | 27.47 | 26.76 |
| 6 | 28.51 | 28.99 | 29.41 | 33.07 | 33.15 | 33.01 | 32.67 | 32.66 | 34.54 | 37.22 | 36.02 | 35.57 | 34.92 | 33.93 |
| 7 | 33.24 | 34.26 | 34.98 | 39.69 | 40.09 | 40.15 | 39.96 | 40.00 | 42.31 | 45.65 | 44.19 | 43.64 | 42.82 | 41.51 |
| 8 | 37.62 | 38.97 | 40.35 | 46.21 | 47.06 | 47.40 | 47.39 | 47.53 | 50.32 | 54.38 | 52.75 | 52.10 | 51.13 | 49.55 |
| 9 | 45.78 | 48.09 | 50.17 | 52.01 | 53.24 | 53.99 | 54.36 | 54.82 | 58.18 | 63.10 | 61.47 | 60.75 | 59.65 | 57.84 |
| 10 | 49.62 | 52.61 | 55.31 | 57.67 | 59.31 | 60.32 | 60.92 | 61.50 | 65.29 | 70.84 | 69.25 | 68.57 | 67.55 | 65.81 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 79.068 | 69.254 |
| SC2 | 0 | 8 | 54.749 | 47.526 |
| SC3 | -18 | 7 | 45.661 | 39.894 |
| SC4 | -25 | 6 | 33.475 | 29.414 |
| SC5 | -34 | 6 | 32.083 | 28.656 |
| A | 3060 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 2665 mm |
| H | 1393 mm |
| I | 3090 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 3060 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.