EK-SR-191DG4-A04 C
60.39 kW
Defrost: None
Product code: EK-SR-291BC4-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 52,930 m³/h |
|---|---|
| External surface | 260.6 m² |
| Inner volume | 53.6 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 695 kg |
| Quantity | 2 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 5,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 69.0 dB(A) |
|---|---|
| Sound power | 93.3 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-291BC4-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 25.21 | 25.19 | 25.19 | 25.19 | 24.99 | 24.74 | 24.44 | 24.69 | 26.09 | 28.14 | 27.38 | 27.10 | 26.71 | 26.13 |
| 5 | 29.17 | 29.72 | 30.13 | 33.68 | 33.69 | 33.46 | 33.06 | 33.36 | 35.33 | 38.12 | 37.05 | 36.68 | 36.13 | 35.25 |
| 6 | 34.85 | 36.00 | 37.03 | 42.16 | 42.74 | 42.90 | 42.56 | 42.87 | 45.42 | 49.01 | 47.53 | 47.00 | 46.24 | 45.09 |
| 7 | 39.79 | 41.59 | 43.19 | 49.51 | 50.43 | 50.91 | 51.04 | 51.63 | 54.82 | 59.43 | 58.05 | 57.52 | 56.75 | 55.52 |
| 8 | 44.36 | 46.90 | ≈ 49.16 | ≈ 56.76 | 58.14 | 58.91 | 59.20 | 59.88 | 63.59 | 68.96 | 67.32 | 66.68 | 65.73 | 64.19 |
| 9 | 53.94 | 57.66 | 60.99 | 63.85 | 65.77 | 66.92 | 67.45 | 68.26 | 72.49 | 78.66 | 76.80 | 76.05 | 74.92 | 73.08 |
| 10 | ≈ 58.17 | 62.84 | 67.08 | 70.74 | 73.28 | 74.89 | 75.72 | 76.71 | 81.50 | 88.50 | 86.45 | 85.59 | 84.30 | 82.15 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 21.92 | 21.75 | 21.63 | 21.62 | 21.51 | 21.33 | 21.11 | 21.49 | 22.77 | 24.61 | 24.03 | 23.82 | 23.51 | 23.06 |
| 5 | 25.36 | 25.53 | 25.69 | 28.70 | 28.62 | 28.37 | 28.05 | 28.38 | 30.11 | 32.55 | 31.71 | 31.42 | 31.02 | 30.43 |
| 6 | 30.82 | 31.36 | 31.93 | 35.98 | 36.12 | 35.97 | 35.61 | 35.90 | 38.05 | 41.08 | 39.85 | 39.42 | 38.81 | 37.90 |
| 7 | 35.50 | 36.67 | 37.74 | 42.98 | 43.59 | 43.87 | 43.62 | 43.91 | 46.51 | 50.23 | 48.67 | 48.08 | 47.23 | 45.88 |
| 8 | 39.76 | 41.49 | 43.03 | 49.31 | 50.22 | 50.68 | 50.76 | 51.28 | 54.43 | 59.01 | 57.52 | 56.91 | 56.01 | 54.33 |
| 9 | 48.58 | 51.20 | 53.54 | 55.55 | 56.83 | 57.53 | 57.75 | 58.33 | 61.90 | 67.14 | 65.35 | 64.61 | 63.52 | 61.68 |
| 10 | 52.63 | 56.01 | 59.05 | 61.65 | 63.38 | 64.38 | 64.78 | 65.46 | 69.47 | 75.33 | 73.32 | 72.46 | 71.18 | 69.01 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 86.449 | 73.317 |
| SC2 | 0 | 8 | 59.879 | 51.284 |
| SC3 | -18 | 7 | 49.941 | 43.269 |
| SC4 | -25 | 6 | 37.034 | 31.925 |
| SC5 | -34 | 6 | 35.142 | 31.013 |
| A | 3060 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 2665 mm |
| H | 1393 mm |
| I | 3090 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 3060 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.