EK-SR-191DG4-A03 C
68.29 kW
Defrost: None
Product code: EK-SR-291BE7-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 50,381 m³/h |
|---|---|
| External surface | 263.6 m² |
| Inner volume | 80.3 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 734 kg |
| Quantity | 2 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 5,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 70.0 dB(A) |
|---|---|
| Sound power | 93.9 dB(A) |
| Energy class | D |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EK-SR-291BE7-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 28.88 | 28.44 | 28.15 | 27.98 | 27.69 | 27.33 | 26.94 | 27.30 | 28.85 | 31.11 | 30.25 | 29.94 | 29.50 | 28.84 |
| 5 | 33.86 | 33.75 | 33.72 | 37.45 | 37.14 | 36.71 | 36.15 | 36.47 | 38.65 | 41.69 | 40.49 | 40.08 | 39.50 | 38.63 |
| 6 | 41.44 | 41.91 | 42.31 | 47.38 | 47.31 | 46.91 | 46.27 | 46.49 | 49.22 | 53.00 | 51.31 | 50.71 | 49.86 | 48.58 |
| 7 | 48.64 | 49.62 | 50.67 | 57.24 | 57.57 | 57.40 | 56.83 | 57.06 | 60.38 | 65.10 | 62.93 | 62.10 | 60.92 | 59.07 |
| 8 | 54.64 | 56.49 | 58.19 | 66.33 | 67.32 | 67.77 | 67.75 | 68.05 | 72.03 | 77.76 | 75.20 | 74.19 | 72.71 | 70.33 |
| 9 | 67.03 | 69.94 | 72.58 | 74.88 | 76.30 | 77.04 | 77.18 | 77.86 | 82.58 | 89.50 | 87.10 | 86.14 | 84.70 | 82.05 |
| 10 | 72.90 | 76.79 | 80.27 | 83.28 | 85.23 | 86.32 | 86.68 | 87.45 | 92.76 | 100.53 | 97.89 | 96.78 | 95.12 | 92.37 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 24.49 | 24.03 | 23.78 | 23.67 | 23.44 | 23.18 | 22.87 | 23.46 | 24.92 | 26.92 | 26.28 | 26.04 | 25.70 | 25.20 |
| 5 | 28.58 | 28.23 | 28.13 | 31.21 | 30.95 | 30.59 | 30.12 | 30.64 | 32.55 | 35.20 | 34.27 | 33.95 | 33.51 | 32.86 |
| 6 | 35.04 | 35.05 | 35.18 | 39.22 | 38.98 | 38.58 | 37.99 | 38.38 | 40.71 | 43.94 | 42.55 | 42.06 | 41.34 | 40.36 |
| 7 | 41.30 | 41.78 | 42.27 | 47.41 | 47.36 | 47.01 | 46.35 | 46.60 | 49.31 | 53.20 | 51.32 | 50.63 | 49.64 | 48.10 |
| 8 | 47.28 | 48.36 | 49.14 | 55.48 | 55.73 | 55.54 | 54.91 | 55.12 | 58.29 | 62.89 | 60.60 | 59.72 | 58.41 | 56.32 |
| 9 | 58.34 | 60.15 | 61.82 | 63.31 | 64.11 | 64.23 | 63.71 | 63.91 | 67.57 | 72.92 | 70.33 | 69.26 | 67.68 | 65.09 |
| 10 | 63.75 | 66.26 | 68.52 | 70.51 | 71.56 | 72.06 | 71.98 | 72.54 | 76.85 | 83.12 | 80.27 | 79.03 | 77.19 | not rated |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 97.892 | 80.266 |
| SC2 | 0 | 8 | 68.052 | 55.121 |
| SC3 | -18 | 7 | 57.439 | 47.413 |
| SC4 | -25 | 6 | 42.314 | 35.180 |
| SC5 | -34 | 6 | 41.599 | 35.091 |
| A | 3060 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 2665 mm |
| H | 1393 mm |
| I | 3090 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 3060 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.