EK-SR-491BC7-A04 C
88.25 kW
Defrost: None
Product code: EK-SR-291DE7-A03 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 64,832 m³/h |
|---|---|
| External surface | 395.5 m² |
| Inner volume | 117.2 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 915 kg |
| Quantity | 2 |
|---|---|
| Diameter | 910 mm |
| Speed | 1,210 rpm |
| Power | 10,400 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 68.0 dB(A) |
|---|---|
| Sound power | 92.0 dB(A) |
| Energy class | E |
| Inlet | Ø28 |
|---|---|
| Outlet | Ø54 |
| EK-SR-291DE7-A03 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 37.00 | 37.09 | 37.11 | 37.25 | 37.14 | 36.85 | 36.47 | 36.62 | 38.75 | 41.78 | 40.60 | 40.16 | 39.54 | 38.59 |
| 5 | 42.26 | 43.10 | 43.82 | 49.33 | 49.49 | 49.32 | 48.88 | 49.00 | 51.88 | 55.97 | 54.36 | 53.78 | 52.93 | 51.62 |
| 6 | 50.67 | 52.53 | 53.81 | 61.24 | 61.98 | 62.19 | 62.00 | 62.20 | 65.86 | 71.12 | 69.04 | 68.26 | 67.13 | 65.36 |
| 7 | 57.89 | 60.63 | 63.11 | 72.55 | 74.15 | 75.12 | 75.53 | 75.94 | 80.48 | 87.05 | 84.65 | 83.71 | 82.31 | 80.05 |
| 8 | 64.36 | 68.14 | ≈ 71.56 | ≈ 82.83 | 85.11 | 86.55 | 87.35 | 88.26 | 93.75 | 101.77 | 99.57 | 98.68 | 97.34 | 95.11 |
| 9 | 78.09 | 83.54 | 88.49 | 92.84 | 95.90 | 97.93 | 99.13 | 100.30 | 106.58 | 115.79 | 113.38 | 112.37 | 110.84 | 108.29 |
| 10 | ≈ 84.05 | 90.83 | 97.05 | 102.52 | 106.48 | 109.17 | 110.86 | 112.37 | 119.47 | 129.87 | 127.32 | 126.21 | 124.52 | 121.64 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 31.29 | 31.13 | 31.10 | 31.16 | 31.05 | 30.84 | 30.57 | 30.80 | 32.67 | 35.32 | 34.47 | 34.13 | 33.66 | 32.94 |
| 5 | 35.96 | 36.20 | 36.48 | 40.78 | 40.81 | 40.63 | 40.30 | 40.48 | 42.89 | 46.34 | 45.08 | 44.62 | 43.98 | 43.01 |
| 6 | 43.35 | 44.22 | 45.01 | 50.78 | 51.08 | 51.03 | 50.68 | 50.84 | 53.84 | 58.15 | 56.48 | 55.81 | 54.90 | 53.50 |
| 7 | 50.31 | 51.98 | 53.20 | 60.51 | 61.27 | 61.52 | 61.38 | 61.59 | 65.22 | 70.49 | 68.44 | 67.65 | 66.48 | 64.61 |
| 8 | 56.73 | 58.88 | 61.08 | 70.06 | 71.50 | 72.19 | 72.30 | 72.65 | 76.97 | 83.29 | 80.95 | 80.02 | 78.63 | 76.35 |
| 9 | 68.91 | 72.52 | 75.80 | 78.69 | 80.65 | 81.84 | 82.49 | 83.26 | 88.38 | 95.90 | 93.72 | 92.66 | 91.07 | 88.41 |
| 10 | 74.59 | 79.22 | 83.42 | 87.11 | 89.64 | 91.29 | 92.22 | 93.20 | 98.97 | 107.41 | 105.07 | 104.05 | 102.51 | 99.89 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 127.321 | 105.067 |
| SC2 | 0 | 8 | 88.259 | 72.645 |
| SC3 | -18 | 7 | 73.279 | 60.879 |
| SC4 | -25 | 6 | 53.806 | 45.012 |
| SC5 | -34 | 6 | 51.139 | 43.598 |
| A | 3060 mm |
|---|---|
| B | 1360 mm |
| C | 3390 mm |
| F | 1310 mm |
| G | 2370 mm |
| E | 2665 mm |
| H | 1393 mm |
| I | 3090 mm |
| D IN | 2 x Ø28 |
| D OUT | 2 x Ø54 |
| Length | 3060 mm |
|---|---|
| Width | 1393 mm |
| Height | 3390 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.