EK-SR-280CG7-A05 C
89.68 kW
Defrost: None
Product code: EK-SR-391BC4-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 79,390 m³/h |
|---|---|
| External surface | 390.9 m² |
| Inner volume | 80.3 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 921 kg |
| Quantity | 3 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 8,400 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 71.0 dB(A) |
|---|---|
| Sound power | 95.3 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EK-SR-391BC4-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 38.06 | 37.99 | 37.96 | 37.94 | 37.64 | 37.26 | 36.80 | 37.16 | 39.27 | 42.35 | 41.21 | 40.79 | 40.20 | 39.32 |
| 5 | 44.08 | 44.85 | 45.28 | 50.77 | 50.75 | 50.39 | 49.78 | 50.22 | 53.19 | 57.38 | 55.77 | 55.21 | 54.39 | 53.05 |
| 6 | 52.64 | 54.31 | 55.83 | 63.50 | 64.35 | 64.62 | 64.09 | 64.54 | 68.39 | 73.79 | 71.55 | 70.74 | 69.60 | 67.86 |
| 7 | 60.14 | 62.78 | 65.13 | 74.60 | 75.95 | 76.64 | 76.81 | 77.68 | 82.49 | 89.42 | 87.32 | 86.52 | 85.35 | 83.50 |
| 8 | 67.10 | 70.84 | ≈ 74.17 | ≈ 85.56 | 87.58 | 88.69 | 89.11 | 90.11 | 95.68 | 103.75 | 101.27 | 100.30 | 98.86 | 96.54 |
| 9 | 81.64 | 87.14 | 92.06 | 96.28 | 99.10 | 100.77 | 101.53 | 102.72 | 109.09 | 118.36 | 115.54 | 114.40 | 112.70 | 109.91 |
| 10 | 88.08 | 95.01 | 101.29 | 106.71 | 110.45 | 112.81 | 114.00 | 115.46 | 122.65 | 133.17 | 130.06 | 128.76 | 126.81 | 123.56 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 33.06 | 32.77 | 32.58 | 32.56 | 32.37 | 32.10 | 31.76 | 32.34 | 34.26 | 37.03 | 36.15 | 35.83 | 35.38 | 34.70 |
| 5 | 38.27 | 38.49 | 38.71 | 43.22 | 43.10 | 42.71 | 42.21 | 42.70 | 45.31 | 48.98 | 47.71 | 47.27 | 46.67 | 45.77 |
| 6 | 46.55 | 47.30 | 48.12 | 54.21 | 54.39 | 54.16 | 53.59 | 54.03 | 57.25 | 61.81 | 59.96 | 59.31 | 58.39 | 57.01 |
| 7 | 53.61 | 55.31 | 56.87 | 64.73 | 65.62 | 66.01 | 65.66 | 66.09 | 69.99 | 75.59 | 73.24 | 72.35 | 71.06 | 69.03 |
| 8 | 60.07 | 62.60 | 64.87 | 74.28 | 75.60 | 76.27 | 76.37 | 77.15 | 81.87 | 88.76 | 86.50 | 85.58 | 84.22 | 81.74 |
| 9 | 73.44 | 77.30 | 80.74 | 83.70 | 85.58 | 86.59 | 86.89 | 87.75 | 93.12 | 100.98 | 98.28 | 97.16 | 95.52 | 92.75 |
| 10 | 79.61 | 84.60 | 89.08 | 92.92 | 95.46 | 96.92 | 97.49 | 98.49 | 104.51 | 113.31 | 110.27 | 108.97 | 107.04 | 103.77 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 130.060 | 110.268 |
| SC2 | 0 | 8 | 90.105 | 77.145 |
| SC3 | -18 | 7 | 75.236 | 65.149 |
| SC4 | -25 | 6 | 55.825 | 48.124 |
| SC5 | -34 | 6 | 53.071 | 46.826 |
| A | 4360 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 3965 mm |
| H | 1393 mm |
| I | 4390 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 4360 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.