EK-SR-391DG7-A04 C
153.97 kW
Defrost: None
Product code: EK-SR-480BG7-A05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 91,184 m³/h |
|---|---|
| External surface | 703.0 m² |
| Inner volume | 204.4 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 1,336 kg |
| Quantity | 4 |
|---|---|
| Diameter | 800 mm |
| Speed | 1,310 rpm |
| Power | 15,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 73.0 dB(A) |
|---|---|
| Sound power | 98.1 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø66,7 |
| EK-SR-480BG7-A05 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 65.35 | 65.42 | 65.42 | 65.66 | 65.43 | 64.90 | 64.16 | 64.77 | 68.70 | 74.19 | 72.17 | 71.41 | 70.32 | 68.67 |
| 5 | 74.50 | 75.82 | 76.96 | 86.55 | 86.75 | 86.36 | 85.46 | 85.98 | 91.10 | 98.36 | 95.51 | 94.50 | 93.06 | 90.85 |
| 6 | 89.27 | 92.26 | 94.35 | 107.18 | 108.31 | 108.48 | 107.90 | 108.46 | 114.88 | 124.07 | 120.30 | 118.90 | 116.86 | 113.67 |
| 7 | 102.13 | 106.65 | 110.74 | 127.07 | 129.62 | 131.05 | 131.03 | 131.81 | 139.67 | 151.03 | 146.60 | 144.86 | 142.26 | 138.08 |
| 8 | 113.63 | 119.91 | ≈ 125.59 | ≈ 145.04 | 148.71 | 150.89 | 151.89 | 153.44 | 162.90 | 176.77 | 172.55 | 170.85 | 168.25 | 163.44 |
| 9 | 137.98 | 147.07 | 155.35 | 162.56 | 167.54 | 170.64 | 172.22 | 174.17 | 184.95 | 200.75 | 196.12 | 194.14 | 191.12 | 186.02 |
| 10 | 148.64 | 160.04 | 170.45 | 179.56 | 185.93 | 190.13 | 192.48 | 194.96 | 207.12 | 224.88 | 219.92 | 217.69 | 214.29 | 208.47 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 57.22 | 56.98 | 56.96 | 57.06 | 56.85 | 56.42 | 55.85 | 56.47 | 59.94 | 64.82 | 63.26 | 62.72 | 61.91 | 60.58 |
| 5 | 65.61 | 66.11 | 66.66 | 74.54 | 74.58 | 74.20 | 73.50 | 73.99 | 78.42 | 84.73 | 82.36 | 81.52 | 80.32 | 78.54 |
| 6 | 78.94 | 80.59 | 82.08 | 92.63 | 93.15 | 92.99 | 92.30 | 92.65 | 98.11 | 105.86 | 102.71 | 101.52 | 99.80 | 97.11 |
| 7 | 91.46 | 94.56 | 96.82 | 110.15 | 111.50 | 111.88 | 111.47 | 111.92 | 118.51 | 128.08 | 124.18 | 122.63 | 120.38 | 116.76 |
| 8 | 102.41 | 106.80 | 110.81 | 127.09 | 129.63 | 131.06 | 131.07 | 131.73 | 139.54 | 150.93 | 146.47 | 144.66 | 141.95 | 137.50 |
| 9 | 124.89 | 131.46 | 137.43 | 142.67 | 146.14 | 148.14 | 149.05 | 150.44 | 159.63 | 173.08 | 168.89 | 167.10 | 163.98 | 158.74 |
| 10 | 135.11 | 143.54 | 151.19 | 157.86 | 162.35 | 165.16 | 166.57 | 168.30 | 178.62 | 193.69 | 189.14 | 187.12 | 184.06 | 178.83 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 219.918 | 189.139 |
| SC2 | 0 | 8 | 153.439 | 131.731 |
| SC3 | -18 | 7 | 128.244 | 110.818 |
| SC4 | -25 | 6 | 94.345 | 82.082 |
| SC5 | -34 | 6 | 90.049 | 79.406 |
| A | 5660 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 5265 mm |
| H | 1393 mm |
| I | 5690 mm |
| D IN | 2 x Ø35 |
| D OUT | 2 x Ø66,7 |
| Length | 5660 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.