EK-SR-391DE7-A04 C
124.41 kW
Defrost: None
Product code: EK-SR-491BE7-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 100,791 m³/h |
|---|---|
| External surface | 527.3 m² |
| Inner volume | 154.9 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 1,216 kg |
| Quantity | 4 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 11,200 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 72.0 dB(A) |
|---|---|
| Sound power | 96.9 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-491BE7-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 52.33 | 52.58 | 52.79 | 52.86 | 52.63 | 52.11 | 51.41 | 52.19 | 55.13 | 59.41 | 57.70 | 57.06 | 56.15 | 54.77 |
| 5 | 59.88 | 61.30 | 62.46 | 70.38 | 70.58 | 70.21 | 69.41 | 70.00 | 74.24 | 80.16 | 77.88 | 77.07 | 75.92 | 74.22 |
| 6 | 71.80 | 74.28 | 76.77 | 87.55 | 88.65 | 88.86 | 88.31 | 89.18 | 94.54 | 102.10 | 99.03 | 97.89 | 96.22 | 93.69 |
| 7 | 81.52 | 85.66 | ≈ 89.39 | ≈ 102.91 | 105.20 | 106.47 | 106.88 | 108.31 | 115.07 | 124.84 | 121.48 | 120.05 | 117.95 | 114.54 |
| 8 | 90.55 | 96.23 | ≈ 101.35 | ≈ 117.52 | 120.83 | 122.78 | 123.62 | 125.30 | 133.12 | 144.51 | 141.09 | 139.70 | 137.62 | 134.16 |
| 9 | 109.77 | 117.91 | 125.31 | 131.74 | 136.21 | 139.01 | 140.40 | 142.41 | 151.34 | 164.42 | 160.54 | 158.93 | 156.49 | 152.38 |
| 10 | ≈ 118.06 | 128.10 | 137.35 | 145.45 | 151.25 | 155.07 | 157.14 | 159.56 | 169.62 | 184.36 | 180.21 | 178.39 | 175.63 | 170.92 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 44.66 | 44.54 | 44.55 | 44.64 | 44.37 | 43.93 | 43.34 | 44.46 | 47.25 | 51.01 | 49.71 | 49.22 | 48.53 | 47.48 |
| 5 | 51.46 | 52.01 | 52.56 | 58.88 | 58.70 | 58.25 | 57.47 | 58.51 | 62.17 | 67.23 | 65.39 | 64.78 | 63.90 | 62.57 |
| 6 | 62.08 | 63.64 | 65.05 | 73.48 | 73.79 | 73.33 | 72.53 | 73.40 | 77.86 | 84.13 | 81.43 | 80.48 | 79.12 | 77.05 |
| 7 | 72.01 | 74.42 | 76.89 | 87.65 | 88.68 | 88.84 | 88.19 | 89.01 | 94.31 | 101.93 | 98.58 | 97.29 | 95.36 | 92.33 |
| 8 | 80.32 | 84.17 | 87.62 | 100.69 | 102.67 | 103.69 | 103.81 | 105.06 | 111.33 | 120.45 | 116.52 | 114.95 | 112.59 | 108.72 |
| 9 | 97.90 | 103.61 | 108.71 | 113.11 | 115.88 | 117.42 | 117.84 | 119.20 | 126.49 | 137.18 | 133.47 | 131.89 | 129.52 | 125.52 |
| 10 | 105.86 | 113.09 | 119.59 | 125.22 | 128.81 | 130.97 | 131.79 | 133.44 | 141.61 | 153.54 | 149.49 | 147.68 | 144.96 | not rated |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 180.210 | 149.491 |
| SC2 | 0 | 8 | 125.295 | 105.057 |
| SC3 | -18 | 7 | 103.968 | 88.139 |
| SC4 | -25 | 6 | 76.769 | 65.048 |
| SC5 | -34 | 6 | 72.537 | 62.507 |
| A | 5660 mm |
|---|---|
| B | 1360 mm |
| C | 2790 mm |
| F | 1310 mm |
| G | 1770 mm |
| E | 5265 mm |
| H | 1393 mm |
| I | 5690 mm |
| D IN | 2 x Ø35 |
| D OUT | 2 x Ø54 |
| Length | 5660 mm |
|---|---|
| Width | 1393 mm |
| Height | 2790 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.