EK-SR-391DG4-A04 C
177.74 kW
Defrost: None
Product code: EK-SR-491DE7-A03 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 129,664 m³/h |
|---|---|
| External surface | 790.9 m² |
| Inner volume | 235.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 1,518 kg |
| Quantity | 4 |
|---|---|
| Diameter | 910 mm |
| Speed | 1,210 rpm |
| Power | 20,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 70.0 dB(A) |
|---|---|
| Sound power | 95.0 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EK-SR-491DE7-A03 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 74.43 | 74.47 | 74.42 | 74.64 | 74.36 | 73.76 | 72.98 | 73.27 | 77.51 | 83.56 | 81.20 | 80.32 | 79.07 | 77.17 |
| 5 | 85.13 | 86.65 | 87.94 | 98.89 | 99.13 | 98.73 | 97.83 | 98.04 | 103.79 | 111.98 | 108.74 | 107.56 | 105.87 | 103.24 |
| 6 | 102.21 | 105.71 | 108.11 | 122.88 | 124.25 | 124.58 | 124.12 | 124.48 | 131.81 | 142.31 | 138.12 | 136.55 | 134.28 | 130.73 |
| 7 | 116.85 | 122.09 | 126.84 | 145.62 | 148.66 | 150.50 | 151.28 | 152.02 | 161.10 | 174.20 | 169.38 | 167.48 | 164.66 | 160.13 |
| 8 | 130.04 | 137.34 | ≈ 143.94 | ≈ 166.35 | 170.71 | 173.45 | 174.96 | 176.70 | 187.66 | 203.68 | 199.24 | 197.45 | 194.74 | 190.26 |
| 9 | 157.93 | 168.52 | 178.12 | 186.56 | 192.47 | 196.32 | 198.60 | 200.84 | 213.39 | 231.79 | 226.89 | 224.86 | 221.77 | 216.64 |
| 10 | ≈ 170.15 | 183.39 | 195.51 | 206.15 | 213.80 | 218.94 | 222.16 | 225.06 | 239.25 | 260.01 | 254.82 | 252.58 | 249.16 | 243.36 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 62.86 | 62.45 | 62.33 | 62.39 | 62.15 | 61.71 | 61.16 | 61.62 | 65.36 | 70.65 | 68.93 | 68.27 | 67.32 | 65.88 |
| 5 | 72.31 | 72.67 | 73.14 | 81.70 | 81.71 | 81.32 | 80.64 | 80.99 | 85.80 | 92.69 | 90.16 | 89.25 | 87.96 | 86.02 |
| 6 | 87.28 | 88.86 | 90.31 | 101.78 | 102.30 | 102.15 | 101.43 | 101.72 | 107.71 | 116.33 | 112.97 | 111.63 | 109.81 | 107.00 |
| 7 | 101.39 | 104.53 | 106.84 | 121.37 | 122.77 | 123.20 | 122.86 | 123.25 | 130.51 | 141.05 | 136.91 | 135.32 | 132.98 | 129.22 |
| 8 | 113.72 | 118.48 | 122.70 | 140.56 | 143.30 | 144.63 | 144.77 | 145.40 | 154.05 | 166.66 | 161.96 | 160.08 | 157.28 | 152.71 |
| 9 | 139.11 | 146.03 | 152.35 | 157.95 | 161.70 | 163.98 | 165.17 | 166.66 | 176.90 | 191.91 | 187.53 | 185.39 | 182.19 | 176.85 |
| 10 | 150.68 | 159.66 | 167.80 | 174.94 | 179.81 | 182.95 | 184.70 | 186.58 | 198.11 | 214.96 | 210.23 | 208.18 | 205.08 | 199.83 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 254.824 | 210.232 |
| SC2 | 0 | 8 | 176.701 | 145.404 |
| SC3 | -18 | 7 | 147.006 | 122.060 |
| SC4 | -25 | 6 | 108.110 | 90.313 |
| SC5 | -34 | 6 | 103.109 | 87.738 |
| A | 5660 mm |
|---|---|
| B | 1360 mm |
| C | 3390 mm |
| F | 1310 mm |
| G | 2370 mm |
| E | 5265 mm |
| H | 1393 mm |
| I | 5690 mm |
| D IN | 2 x Ø42 |
| D OUT | 2 x Ø66,7 |
| Length | 5660 mm |
|---|---|
| Width | 1393 mm |
| Height | 3390 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.