EA-G-263FE4-A19 C
41.53 kW
Defrost: None
Product code: EA-G-363FC7-A08 C
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Air flow | 47,788 m³/h |
|---|---|
| Air throw | 42 m |
| External surface | 168.7 m² |
| Inner volume | 51.8 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 247 kg |
| Quantity | 3 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 5,700 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 74.0 dB(A) |
|---|---|
| Sound power | 97.0 dB(A) |
| Energy class | E |
| Inlet | 2" |
|---|---|
| Outlet | 2" |
| EA-G-363FC7-A08 C | None |
|---|
ΔT (air inlet − fluid inlet) must be within 6–12 K (fluid outlet = inlet + 3 K); air inlet -25…10 °C. Points below the fluid's freezing point are not rated.
ETHYLENE GLYCOL 30% -10 → -7 °C, air inlet 0 °C (ΔT 10 K)
ETHYLENE GLYCOL 30%; rows: ΔT = air inlet − fluid inlet [K], outlet = inlet + 3 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | 9.75 | ≈ 9.28 | ≈ 9.33 | ≈ 14.81 |
| 8 | not rated | not rated | not rated | not rated | ≈ 16.28 | ≈ 25.94 | ≈ 29.68 | ≈ 32.17 |
| 10 | not rated | not rated | not rated | not rated | ≈ 39.04 | 41.59 | 44.20 | 48.52 |
| 12 | not rated | not rated | not rated | not rated | not rated | 55.18 | 58.78 | 63.98 |
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | 9.30 | ≈ 8.74 | ≈ 8.78 | ≈ 8.80 |
| 8 | not rated | not rated | not rated | not rated | ≈ 15.41 | ≈ 21.94 | ≈ 26.20 | ≈ 28.72 |
| 10 | not rated | not rated | not rated | not rated | ≈ 33.70 | 36.75 | 39.41 | 43.41 |
| 12 | not rated | not rated | not rated | not rated | not rated | 48.99 | 52.49 | 57.22 |
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Fan connection | Cooling capacity [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 41.589 | 13.06 | 78.4 |
| Low speed (Y) | 36.745 | 11.54 | 62.9 |
| A | 3415 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| G | 935 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 3035 mm |
| D IN | 2" |
| D OUT | 2" |
| Length | 3415 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.