Skip to Content

Brine cooler EA-G-663EC10-A06 C

Brine cooler EA-G-663EC10-A06 C
Illustrative photo

Producer: Karyer · Line: EA-G (General)

Product code: EA-G-663EC10-A06 C

Cooling capacity i
45.00 kW
Air flow
55,704 m³/h
Fin spacing
10.0 mm
Air throw
28 m
Fans
6 × ⌀630 mm

Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %

Data

Coil
Air flow 55,704 m³/h
Air throw 28 m
External surface 195.3 m²
Inner volume 88.5 dm³
Fin spacing 10.0 mm
Fin materialAluminium
Net weight 399 kg
Fans
Quantity 6
Diameter 630 mm
Speed 890 rpm
Power 3,600 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 58.0 dB(A)
Sound power 81.8 dB(A)
Energy class E
Connections
Inlet 3"
Outlet 3"
Defrost
EA-G-663EC10-A06 C None

Performance

Fluid -10 → -7 °C

ΔT (air inlet − fluid inlet) must be within 6–12 K (fluid outlet = inlet + 3 K); air inlet -25…10 °C. Points below the fluid's freezing point are not rated.

ETHYLENE GLYCOL 30% -10 → -7 °C, air inlet 0 °C (ΔT 10 K)

Cooling capacity · High speed (Δ)
44.998 kW Sensible capacity 33.257 kW Fluid flow 14.13 m³/h Pressure drop 41.0 kPa
Cooling capacity · Low speed (Y)
37.992 kW Sensible capacity 28.014 kW Fluid flow 11.93 m³/h Pressure drop 30.4 kPa

Cooling capacity [kW]: Air inlet × ΔT (air − fluid inlet), fluid range 3 K

ETHYLENE GLYCOL 30%; rows: ΔT = air inlet − fluid inlet [K], outlet = inlet + 3 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

≈ 1.23 estimate — vendor data irregular here

High speed (Δ)

Cooling capacity [kW]: Air inlet × ΔT (air − fluid inlet), fluid range 3 K
ΔT [K] \ air [°C] -25-20-15-10-50510
6 not rated not rated not rated not rated 11.61 11.48 ≈ 11.52 ≈ 11.52
8 not rated not rated not rated not rated 19.14 ≈ 18.33 ≈ 31.79 ≈ 36.07
10 not rated not rated not rated not rated ≈ 27.04 45.00 49.53 55.07
12 not rated not rated not rated not rated not rated 60.95 66.18 72.64

Low speed (Y)

Cooling capacity [kW]: Air inlet × ΔT (air − fluid inlet), fluid range 3 K
ΔT [K] \ air [°C] -25-20-15-10-50510
6 not rated not rated not rated not rated 10.95 10.66 10.69 ≈ 10.68
8 not rated not rated not rated not rated 17.92 ≈ 16.90 ≈ 16.92 ≈ 31.34
10 not rated not rated not rated not rated ≈ 25.17 37.99 ≈ 43.09 48.32
12 not rated not rated not rated not rated not rated 52.66 57.87 63.82

Nominal rating

Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %

Fan connection Cooling capacity [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 44.998 14.13 41.0
Low speed (Y) 37.992 11.93 30.4

Dimensions

Dimension drawing of EA-G-663EC10-A06 C
Dimension drawing
Dimensions as drawn
A 5215 mm
B 900 mm
C 1190 mm
F 860 mm
E1 818 mm
E2 800 mm
E 4835 mm
D IN 3"
D OUT 3"
Overall [mm]
Length 5215 mm
Width 900 mm
Height 1190 mm

Downloads