ED-G-350AE7-A21 C
40.05 kW
Defrost: None
Product code: ED-G-263AG4-A27 C
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Air flow | 15,428 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 320.8 m² |
| Inner volume | 66.3 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 277 kg |
| Quantity | 2 |
|---|---|
| Diameter | 630 mm |
| Speed | 890 rpm |
| Power | 1,200 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 54.0 dB(A) |
|---|---|
| Sound power | 77.0 dB(A) |
| Energy class | E |
| Inlet | 2" |
|---|---|
| Outlet | 2" |
| ED-G-263AG4-A27 C | None |
|---|
ΔT (air inlet − fluid inlet) must be within 6–12 K (fluid outlet = inlet + 3 K); air inlet -25…10 °C. Points below the fluid's freezing point are not rated.
ETHYLENE GLYCOL 30% -10 → -7 °C, air inlet 0 °C (ΔT 10 K)
ETHYLENE GLYCOL 30%; rows: ΔT = air inlet − fluid inlet [K], outlet = inlet + 3 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | 12.56 | 11.29 | ≈ 11.32 | ≈ 11.28 |
| 8 | not rated | not rated | not rated | not rated | 20.34 | ≈ 19.03 | ≈ 30.40 | ≈ 34.37 |
| 10 | not rated | not rated | not rated | not rated | 38.14 | 42.25 | 45.83 | 50.23 |
| 12 | not rated | not rated | not rated | not rated | not rated | 55.29 | 59.77 | 65.14 |
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | 11.34 | 9.98 | ≈ 9.98 | ≈ 9.91 |
| 8 | not rated | not rated | not rated | not rated | 18.09 | ≈ 17.10 | ≈ 23.35 | ≈ 27.79 |
| 10 | not rated | not rated | not rated | not rated | ≈ 24.93 | 33.31 | 36.93 | 40.74 |
| 12 | not rated | not rated | not rated | not rated | not rated | 44.20 | 48.25 | 52.73 |
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Fan connection | Cooling capacity [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 42.245 | 13.25 | 57.1 |
| Low speed (Y) | 33.305 | 10.44 | 37.5 |
| A | 2828 mm |
|---|---|
| B | 1720 mm |
| C | 455 mm |
| F | 1645 mm |
| G | 483 mm |
| E1 | 2435 mm |
| E2 | 1218 mm |
| D IN | 2" |
| D OUT | 2" |
| Length | 2828 mm |
|---|---|
| Width | 1720 mm |
| Height | 483 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.