Skip to Content

ED-G (General)

Application
Ceiling mounted (flat), Industrial
Air discharge
Dual
Refrigerants
ETHYLENE GLYCOL 10%, ETHYLENE GLYCOL 11%, ETHYLENE GLYCOL 12%, ETHYLENE GLYCOL 13%, ETHYLENE GLYCOL 14%, ETHYLENE GLYCOL 15%, ETHYLENE GLYCOL 16%, ETHYLENE GLYCOL 17%, ETHYLENE GLYCOL 18%, ETHYLENE GLYCOL 19%, ETHYLENE GLYCOL 20%, ETHYLENE GLYCOL 21%, ETHYLENE GLYCOL 22%, ETHYLENE GLYCOL 23%, ETHYLENE GLYCOL 24%, ETHYLENE GLYCOL 25%, ETHYLENE GLYCOL 26%, ETHYLENE GLYCOL 27%, ETHYLENE GLYCOL 28%, ETHYLENE GLYCOL 29%, ETHYLENE GLYCOL 30%, ETHYLENE GLYCOL 31%, ETHYLENE GLYCOL 32%, ETHYLENE GLYCOL 33%, ETHYLENE GLYCOL 34%, ETHYLENE GLYCOL 35%, ETHYLENE GLYCOL 36%, ETHYLENE GLYCOL 37%, ETHYLENE GLYCOL 38%, ETHYLENE GLYCOL 39%, ETHYLENE GLYCOL 40%, ETHYLENE GLYCOL 41%, ETHYLENE GLYCOL 42%, ETHYLENE GLYCOL 43%, ETHYLENE GLYCOL 44%, ETHYLENE GLYCOL 45%, ETHYLENE GLYCOL 46%, ETHYLENE GLYCOL 47%, ETHYLENE GLYCOL 48%, ETHYLENE GLYCOL 49%, ETHYLENE GLYCOL 5%, ETHYLENE GLYCOL 50%, ETHYLENE GLYCOL 6%, ETHYLENE GLYCOL 7%, ETHYLENE GLYCOL 8%, ETHYLENE GLYCOL 9%, OIL ISO VG 100, OIL ISO VG 150, OIL ISO VG 220, OIL ISO VG 32, OIL ISO VG 320, OIL ISO VG 46, OIL ISO VG 460, OIL ISO VG 68, OIL SAE 10, OIL SAE 20, OIL SAE 30, OIL SAE 40, OIL SAE 50, OIL SAE 60, OIL SAE 70, PROPYLENE GLYCOL 15%, PROPYLENE GLYCOL 20%, PROPYLENE GLYCOL 25%, PROPYLENE GLYCOL 30%, PROPYLENE GLYCOL 35%, PROPYLENE GLYCOL 40%, PROPYLENE GLYCOL 45%, PROPYLENE GLYCOL 50%, TEMPER, TEMPER-10, TEMPER-20, TEMPER-30, TEMPER-40, TEMPER-55, WATER
Capacity
1.53–70.94 kW
Fans
⌀300, ⌀350, ⌀400, ⌀450, ⌀500, ⌀630 mm
Max. working pressure
10 bar
ED-G (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • B
    Number of fans — Digit 1-9.
  • C
    Fan diameter — Two digits = diameter / 10 (91 = Ø910). 30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm50 = Ø500 mm63 = Ø630 mm
  • E
    Coil tube rows (2nd dimensional letter) C = 4 tube rowsE = 6 tube rowsG = 8 tube rows
  • F
    Fin spacing 4 = 4.2-4.6 mm7 = 7.0 mm
  • G
    Generation code — Catalogue: "Generation Code". A = generation A
  • H
    Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 21 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)23 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)25 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)27 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
Model Cooling capacity [kW] i Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 % Fans Air throw [m] Air flow [m³/h] Variants
ED-G-345AC4-A23 C 25.35 kW 3 × ⌀450 14 13,992
Variants (1)
ED-G-250AE7-A21 C 25.50 kW 2 × ⌀500 14 14,146
Variants (1)
ED-G-250AE4-A21 C 27.41 kW 2 × ⌀500 14 13,278
Variants (1)
ED-G-440AE4-A21 C 28.72 kW 4 × ⌀400 12 11,821
Variants (1)
ED-G-250AG7-A21 C 28.83 kW 2 × ⌀500 13 13,215
Variants (1)
ED-G-445AC4-A23 C 28.92 kW 4 × ⌀450 17 18,665
Variants (1)
ED-G-263AE7-A27 C 28.97 kW 2 × ⌀630 16 17,588
Variants (1)
ED-G-345AE4-A23 C 30.49 kW 3 × ⌀450 13 12,758
Variants (1)
ED-G-263AG7-A27 C 33.98 kW 2 × ⌀630 15 16,467
Variants (1)
ED-G-250AG4-A21 C 35.63 kW 2 × ⌀500 13 12,278
Variants (1)
ED-G-263AE4-A27 C 37.56 kW 2 × ⌀630 15 16,703
Variants (1)
ED-G-350AE4-A21 C 39.49 kW 3 × ⌀500 17 19,921
Variants (1)
ED-G-350AE7-A21 C 40.05 kW 3 × ⌀500 18 21,216
Variants (1)
ED-G-263AG4-A27 C 42.25 kW 2 × ⌀630 14 15,428
Variants (1)
ED-G-363AE7-A27 C 45.81 kW 3 × ⌀630 20 26,377
Variants (1)
ED-G-350AG7-A21 C 46.10 kW 3 × ⌀500 17 19,818
Variants (1)
ED-G-450AE7-A21 C 50.58 kW 4 × ⌀500 21 28,293
Variants (1)
ED-G-363AG7-A27 C 54.38 kW 3 × ⌀630 19 24,694
Variants (1)
ED-G-350AG4-A21 C 55.94 kW 3 × ⌀500 16 18,415
Variants (1)
ED-G-450AG7-A21 C 57.32 kW 4 × ⌀500 20 26,431
Variants (1)
ED-G-363AE4-A27 C 58.65 kW 3 × ⌀630 19 25,051
Variants (1)
ED-G-450AE4-A21 C 64.84 kW 4 × ⌀500 20 26,540
Variants (1)
ED-G-363AG4-A27 C 66.40 kW 3 × ⌀630 18 23,138
Variants (1)
ED-G-450AG4-A21 C 70.94 kW 4 × ⌀500 19 24,556
Variants (1)

Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %

Downloads