Skip to Content

EG-G (General)

Application
Ceiling mounted (slanted), Industrial
Air discharge
Single
Refrigerants
ETHYLENE GLYCOL 10%, ETHYLENE GLYCOL 11%, ETHYLENE GLYCOL 12%, ETHYLENE GLYCOL 13%, ETHYLENE GLYCOL 14%, ETHYLENE GLYCOL 15%, ETHYLENE GLYCOL 16%, ETHYLENE GLYCOL 17%, ETHYLENE GLYCOL 18%, ETHYLENE GLYCOL 19%, ETHYLENE GLYCOL 20%, ETHYLENE GLYCOL 21%, ETHYLENE GLYCOL 22%, ETHYLENE GLYCOL 23%, ETHYLENE GLYCOL 24%, ETHYLENE GLYCOL 25%, ETHYLENE GLYCOL 26%, ETHYLENE GLYCOL 27%, ETHYLENE GLYCOL 28%, ETHYLENE GLYCOL 29%, ETHYLENE GLYCOL 30%, ETHYLENE GLYCOL 31%, ETHYLENE GLYCOL 32%, ETHYLENE GLYCOL 33%, ETHYLENE GLYCOL 34%, ETHYLENE GLYCOL 35%, ETHYLENE GLYCOL 36%, ETHYLENE GLYCOL 37%, ETHYLENE GLYCOL 38%, ETHYLENE GLYCOL 39%, ETHYLENE GLYCOL 40%, ETHYLENE GLYCOL 41%, ETHYLENE GLYCOL 42%, ETHYLENE GLYCOL 43%, ETHYLENE GLYCOL 44%, ETHYLENE GLYCOL 45%, ETHYLENE GLYCOL 46%, ETHYLENE GLYCOL 47%, ETHYLENE GLYCOL 48%, ETHYLENE GLYCOL 49%, ETHYLENE GLYCOL 5%, ETHYLENE GLYCOL 50%, ETHYLENE GLYCOL 6%, ETHYLENE GLYCOL 7%, ETHYLENE GLYCOL 8%, ETHYLENE GLYCOL 9%, OIL ISO VG 100, OIL ISO VG 150, OIL ISO VG 220, OIL ISO VG 32, OIL ISO VG 320, OIL ISO VG 46, OIL ISO VG 460, OIL ISO VG 68, OIL SAE 10, OIL SAE 20, OIL SAE 30, OIL SAE 40, OIL SAE 50, OIL SAE 60, OIL SAE 70, PROPYLENE GLYCOL 15%, PROPYLENE GLYCOL 20%, PROPYLENE GLYCOL 25%, PROPYLENE GLYCOL 30%, PROPYLENE GLYCOL 35%, PROPYLENE GLYCOL 40%, PROPYLENE GLYCOL 45%, PROPYLENE GLYCOL 50%, TEMPER, TEMPER-10, TEMPER-20, TEMPER-30, TEMPER-40, TEMPER-55, WATER
Capacity
0.77–9.48 kW
Fans
⌀250, ⌀300, ⌀350 mm
Max. working pressure
10 bar
EG-G (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • B
    Number of fans — Digit 1-9.
  • C
    Fan diameter — Two digits = diameter / 10 (91 = Ø910). 25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm
  • E
    Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsE = 6 tube rowsG = 8 tube rows
  • F
    Fin spacing 4 = 4.2-4.6 mm7 = 7.0 mm
  • G
    Generation code — Catalogue: "Generation Code". A = generation A
  • H
    Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 21 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)23 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)25 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)
Model Cooling capacity [kW] i Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 % Fans Air throw [m] Air flow [m³/h] Variants
EG-G-235CG7-A21 C 6.07 kW 2 × ⌀350 13 3,597
Variants (1)
EG-G-430BE7-A25 C 6.07 kW 4 × ⌀300 12 3,958
Variants (1)
EG-G-335CE7-A21 C 6.15 kW 3 × ⌀350 18 6,076
Variants (1)
EG-G-430AE4-A21 C 6.43 kW 4 × ⌀300 13 4,254
Variants (1)
EG-G-430BE7-A21 C 6.51 kW 4 × ⌀300 14 4,640
Variants (1)
EG-G-235CG4-A21 C 6.66 kW 2 × ⌀350 11 3,188
Variants (1)
EG-G-335CE4-A21 C 6.83 kW 3 × ⌀350 16 5,490
Variants (1)
EG-G-430BE4-A25 C 6.85 kW 4 × ⌀300 11 3,618
Variants (1)
EG-G-335BE7-A21 C 6.85 kW 3 × ⌀350 18 6,451
Variants (1)
EG-G-430BE4-A21 C 7.34 kW 4 × ⌀300 13 4,250
Variants (1)
EG-G-335BE4-A21 C 7.64 kW 3 × ⌀350 16 5,901
Variants (1)
EG-G-335CG7-A21 C 8.67 kW 3 × ⌀350 16 5,397
Variants (1)
EG-G-335BC4-A21 C 8.96 kW 3 × ⌀350 19 6,767
Variants (1)
EG-G-335CG4-A21 C 9.48 kW 3 × ⌀350 14 4,784
Variants (1)

Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.