- Catalogue
- CO₂ DX evaporators
- ED-DC (Double Flow)
- ED-DC-335AC7-A21 C
CO2 evaporator ED-DC-335AC7-A21 C
Defrost: None
Product code: ED-DC-335AC7-A21 C
- Fin spacing
- 7.0 mm
- Fans
- 3 × ⌀350 mm
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
Data
| External surface | 29.8 m² |
|---|---|
| Inner volume | 7.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 91 kg |
| Quantity | 3 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 495 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | C |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø19 |
| ED-DC-335AC7-A21 C | None |
|---|
Performance
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R744, dew point -8 °C, air inlet 0 °C (TD 8 K)
- Single phase
- 9.597 kW
Capacity matrix [kW]
R744, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
Single phase
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.05 | 4.05 | 4.11 | 4.21 | 4.30 | 4.38 | 4.45 | 4.58 | 4.90 | 5.38 | 5.37 | 5.37 | 5.38 | 5.40 |
| 5 | 5.07 | 5.12 | 5.21 | 5.35 | 5.48 | 5.59 | 5.68 | 5.83 | 6.23 | 6.83 | 6.80 | 6.79 | 6.78 | 6.78 |
| 6 | 6.08 | 6.16 | 6.31 | 6.49 | 6.66 | 6.80 | 6.92 | 7.08 | 7.57 | 8.29 | 8.24 | 8.22 | 8.20 | 8.17 |
| 7 | 7.06 | 7.19 | 7.38 | 7.62 | 7.82 | 8.00 | 8.15 | 8.34 | 8.91 | 9.76 | 9.69 | 9.67 | 9.63 | 9.57 |
| 8 | 8.01 | 8.18 | 8.43 | 8.72 | 8.98 | 9.20 | 9.38 | 9.60 | 10.25 | 11.22 | 11.15 | 11.12 | 11.07 | 10.98 |
| 9 | 8.92 | 9.15 | 9.46 | 9.82 | 10.12 | 10.38 | 10.61 | 10.85 | 11.59 | 12.69 | 12.61 | 12.57 | 12.51 | 12.40 |
| 10 | 9.79 | 10.09 | 10.47 | 10.88 | 11.24 | 11.56 | 11.82 | 12.11 | 12.93 | 14.16 | 14.07 | 14.03 | 13.96 | 13.83 |
Standard ratings (EN 328 / Eurovent)
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 14.073 |
| SC2 | 0 | 8 | 9.597 |
| SC3 | -18 | 7 | 7.702 |
| SC4 | -25 | 6 | 6.309 |
| SC5 | -34 | 6 | 6.101 |
Dimensions
| A | 2148 mm |
|---|---|
| B | 1030 mm |
| C | 285 mm |
| F | 985 mm |
| G | 367 mm |
| E1 | 1835 mm |
| E2 | 618 mm |
| E3 | 600 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø19 |
| Length | 2148 mm |
|---|---|
| Width | 1030 mm |
| Height | 367 mm |
Downloads
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.