Skip to Content

Condenser KA/KB-480FC1-B01I C

Condenser KA/KB-480FC1-B01I C
Illustrative photo

Producer: Karyer · Line: KA/KB (General)

Product code: KA/KB-480FC1-B01I C

Heat rejection i
281.35 kW
Air flow
74,045 m³/h
Fin spacing
2.1 mm
Fans
4 × ⌀800 mm

Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: KA/KB — KA = vertical, KB = horizontal industrial condenser.
  • D
    Number of fans per row: 4 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 80 — Ø800 mm
  • G
    Coil tube rows (2nd dimensional letter): C — 4 tube rows
  • H
    Fin spacing: 1 — 2.1 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 01 — fan motor code; supply/poles vary with diameter

Data

Coil
Air flow 74,045 m³/h
External surface 961.0 m²
Inner volume 107.4 dm³
Fin spacing 2.1 mm
Fin materialAluminium
Net weight 826 kg
Fans
Quantity 4
Diameter 800 mm
Speed 880 rpm
Power 7,828 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 54.0 dB(A)
Sound power 86.1 dB(A)
Energy class D
Connections
Inlet Ø54
Outlet Ø35
Defrost
KA/KB-480FC1-B01I C None

Performance

Condensing 40 °C

ΔT (condensing − air inlet) must be within 8–20 K; air inlet 25…50 °C.

R404A, dew point, air inlet 25 °C, ΔT 15 K (condensing 40 °C); Vendor rating (gas inlet superheat 26 K, no subcooling)

Heat rejection · Single phase
284.941 kW Refrigerant flow 6,673 kg/h

Heat rejection at ΔT 15 K [kW]

R404A, Vendor rating (gas inlet superheat 26 K, no subcooling); one row per fan connection; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

Heat rejection at ΔT 15 K [kW]
Fan connection \ air [°C] 253035404550
Single phase 284.94 284.90 285.73 287.71 291.36 297.77

Nominal rating

Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %

Fan connection Heat rejection [kW]
Single phase 284.941

Dimensions

Dimension drawing of KA/KB-480FC1-B01I C
Dimension drawing
Dimensions as drawn
A 7300 mm
B 1350 mm
C 1240 mm
F 1050 mm
G 450 mm
E 7100 mm
H 1750 mm
I 1190 mm
D IN Ø54
D OUT Ø35
Overall [mm]
Length 7300 mm
Width 1240 mm
Height 1350 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.