Skip to Content

Condenser KA/KB-680CD1-B01 C

Condenser KA/KB-680CD1-B01 C
Illustrative photo

Producer: Karyer · Line: KA/KB (General)

Product code: KA/KB-680CD1-B01 C

Heat rejection i
360.03 kW
Air flow
90,205 m³/h
Fin spacing
2.1 mm
Fans
6 × ⌀800 mm

Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: KA/KB — KA = vertical, KB = horizontal industrial condenser.
  • D
    Number of fans per row: 6 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 80 — Ø800 mm
  • G
    Coil tube rows (2nd dimensional letter): D — 5 tube rows
  • H
    Fin spacing: 1 — 2.1 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 01 — fan motor code; supply/poles vary with diameter

Data

Coil
Air flow 90,205 m³/h
External surface 814.2 m²
Inner volume 87.0 dm³
Fin spacing 2.1 mm
Fin materialAluminium
Net weight 858 kg
Fans
Quantity 6
Diameter 800 mm
Speed 900 rpm
Power 10,800 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 59.0 dB(A)
Sound power 90.8 dB(A)
Energy class E
Connections
Inlet Ø66,7
Outlet Ø54
Defrost
KA/KB-680CD1-B01 C None

Performance

Condensing 40 °C

ΔT (condensing − air inlet) must be within 8–20 K; air inlet 25…50 °C.

R404A, dew point, air inlet 25 °C, ΔT 15 K (condensing 40 °C); Vendor rating (gas inlet superheat 26 K, no subcooling)

Heat rejection · High speed (Δ)
364.380 kW Refrigerant flow 8,533 kg/h
Heat rejection · Low speed (Y)
273.369 kW Refrigerant flow 6,402 kg/h

Heat rejection at ΔT 15 K [kW]

R404A, Vendor rating (gas inlet superheat 26 K, no subcooling); one row per fan connection; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

Heat rejection at ΔT 15 K [kW]
Fan connection \ air [°C] 253035404550
High speed (Δ) 364.38 365.35 367.15 370.06 374.58 381.70
Low speed (Y) 273.37 273.75 274.74 276.53 279.71 284.38

Nominal rating

Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %

Fan connection Heat rejection [kW]
High speed (Δ) 364.380
Low speed (Y) 273.369

Dimensions

Dimension drawing of KA/KB-680CD1-B01 C
Dimension drawing
Dimensions as drawn
A 6600 mm
B 1350 mm
C 1230 mm
F 1050 mm
G 450 mm
E 6400 mm
H 1050 mm
I 1180 mm
D IN Ø66,7
D OUT Ø54
Overall [mm]
Length 6600 mm
Width 1230 mm
Height 1350 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.