- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-480CB5-B03 C | 110.90 kW | 4 × ⌀800 | 36,230 |
Variants (1) |
| KA/KB-550BB1-B10 C | 110.92 kW | 5 × ⌀500 | 35,997 |
Variants (1) |
| KA/KB-t-280EC5-B01I C | 110.95 kW | 2 × ⌀800 | 29,932 |
Variants (1) |
| KA/KB-280CD5-B01 C | 111.18 kW | 2 × ⌀800 | 31,284 |
Variants (1) |
| KA/KB-2x350AB5-B01I C | 111.21 kW | 6 × ⌀500 | 41,267 |
Variants (1) |
| KA/KB-2x350AB5-B10 C | 111.33 kW | 6 × ⌀500 | 41,454 |
Variants (1) |
| KA/KB-550BB1-B01I C | 111.35 kW | 5 × ⌀500 | 35,843 |
Variants (1) |
| KA/KB-t-2x263EA5-B19 C | 111.37 kW | 4 × ⌀630 | 48,912 |
Variants (1) |
| KA/KB-t-2x163HB1-B19 C | 111.77 kW | 2 × ⌀630 | 25,501 |
Variants (1) |
| KA/KB-2x180AC5-B01I C | 111.80 kW | 2 × ⌀800 | 33,391 |
Variants (1) |
| KA/KB-191DC1-B04 C | 111.89 kW | 1 × ⌀910 | 29,398 |
Variants (1) |
| KA/KB-191DC1-B04I C | 111.93 kW | 1 × ⌀910 | 29,414 |
Variants (1) |
| KA/KB-380GB5-B03 C | 112.01 kW | 3 × ⌀800 | 32,230 |
Variants (1) |
| KA/KB-280AC5-B01I C | 112.04 kW | 2 × ⌀800 | 33,391 |
Variants (1) |
| KA/KB-363AB5-B08 C | 112.43 kW | 3 × ⌀630 | 45,336 |
Variants (1) |
| KA/KB-t-363HA1-B01 C | 112.45 kW | 3 × ⌀630 | 30,096 |
Variants (1) |
| KA/KB-2x250BD1-B09 C | 112.45 kW | 4 × ⌀500 | 25,346 |
Variants (1) |
| KA/KB-191HD5-B04 C | 112.50 kW | 1 × ⌀910 | 29,066 |
Variants (1) |
| KA/KB-191HD5-B04I C | 112.65 kW | 1 × ⌀910 | 29,113 |
Variants (1) |
| KA/KB-2x250CD1-B09 C | 112.68 kW | 4 × ⌀500 | 25,679 |
Variants (1) |
| KA/KB-450BD1-B09 C | 112.70 kW | 4 × ⌀500 | 25,346 |
Variants (1) |
| KA/KB-363BD1-B06I C | 112.71 kW | 3 × ⌀630 | 23,880 |
Variants (1) |
| KA/KB-2x191FB5-B04 C | 112.72 kW | 2 × ⌀910 | 53,558 |
Variants (1) |
| KA/KB-2x263AB5-B06I C | 112.93 kW | 4 × ⌀630 | 34,950 |
Variants (1) |
| KA/KB-2x191FB5-B04I C | 112.96 kW | 2 × ⌀910 | 53,757 |
Variants (1) |
| KA/KB-463AB5-B06I C | 113.12 kW | 4 × ⌀630 | 34,950 |
Variants (1) |
| KA/KB-363BD1-B01 C | 113.22 kW | 3 × ⌀630 | 23,999 |
Variants (1) |
| KA/KB-380AC5-B03 C | 113.29 kW | 3 × ⌀800 | 26,328 |
Variants (1) |
| KA/KB-t-2x180EC5-B01 C | 113.43 kW | 2 × ⌀800 | 31,114 |
Variants (1) |
| KA/KB-2x180GB5-B01 C | 113.46 kW | 2 × ⌀800 | 43,576 |
Variants (1) |
| KA/KB-2x163GB1-B08 C | 113.63 kW | 2 × ⌀630 | 33,732 |
Variants (1) |
| KA/KB-450CD1-B09 C | 113.68 kW | 4 × ⌀500 | 25,867 |
Variants (1) |
| KA/KB-291FB5-B04 C | 113.75 kW | 2 × ⌀910 | 53,838 |
Variants (1) |
| KA/KB-550AC1-B09 C | 113.92 kW | 5 × ⌀500 | 30,673 |
Variants (1) |
| KA/KB-291FB5-B04I C | 113.98 kW | 2 × ⌀910 | 54,028 |
Variants (1) |
| KA/KB-2x163GC1-B19 C | 114.11 kW | 2 × ⌀630 | 25,406 |
Variants (1) |
| KA/KB-280GB5-B01 C | 114.29 kW | 2 × ⌀800 | 43,704 |
Variants (1) |
| KA/KB-263GB1-B08 C | 114.29 kW | 2 × ⌀630 | 33,785 |
Variants (1) |
| KA/KB-t-480EA1-B03 C | 114.31 kW | 4 × ⌀800 | 37,056 |
Variants (1) |
| KA/KB-t-380EA1-B01 C | 114.42 kW | 3 × ⌀800 | 56,477 |
Variants (1) |
| KA/KB-2x263AB5-B01 C | 114.46 kW | 4 × ⌀630 | 35,664 |
Variants (1) |
| KA/KB-463AB5-B01 C | 114.66 kW | 4 × ⌀630 | 35,664 |
Variants (1) |
| KA/KB-263GC1-B19 C | 114.78 kW | 2 × ⌀630 | 25,437 |
Variants (1) |
| KA/KB-t-280EC5-B01 C | 114.80 kW | 2 × ⌀800 | 31,375 |
Variants (1) |
| KA/KB-550AC1-B10 C | 114.97 kW | 5 × ⌀500 | 31,643 |
Variants (1) |
| KA/KB-2x250CD1-B10 C | 114.99 kW | 4 × ⌀500 | 26,484 |
Variants (1) |
| KA/KB-2x250BD1-B01I C | 115.00 kW | 4 × ⌀500 | 26,028 |
Variants (1) |
| KA/KB-2x250CD1-B01I C | 115.13 kW | 4 × ⌀500 | 26,346 |
Variants (1) |
| KA/KB-450BD1-B01I C | 115.23 kW | 4 × ⌀500 | 26,028 |
Variants (1) |
| KA/KB-450CD1-B10 C | 115.87 kW | 4 × ⌀500 | 26,676 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-480CB5-B03 C — product datasheet (PDF)
- KA/KB-550BB1-B10 C — product datasheet (PDF)
- KA/KB-t-280EC5-B01I C — product datasheet (PDF)
- KA/KB-280CD5-B01 C — product datasheet (PDF)
- KA/KB-2x350AB5-B01I C — product datasheet (PDF)
- KA/KB-2x350AB5-B10 C — product datasheet (PDF)
- KA/KB-550BB1-B01I C — product datasheet (PDF)
- KA/KB-t-2x263EA5-B19 C — product datasheet (PDF)
- KA/KB-t-2x163HB1-B19 C — product datasheet (PDF)
- KA/KB-2x180AC5-B01I C — product datasheet (PDF)
- KA/KB-191DC1-B04 C — product datasheet (PDF)
- KA/KB-191DC1-B04I C — product datasheet (PDF)
- KA/KB-380GB5-B03 C — product datasheet (PDF)
- KA/KB-280AC5-B01I C — product datasheet (PDF)
- KA/KB-363AB5-B08 C — product datasheet (PDF)
- KA/KB-t-363HA1-B01 C — product datasheet (PDF)
- KA/KB-2x250BD1-B09 C — product datasheet (PDF)
- KA/KB-191HD5-B04 C — product datasheet (PDF)
- KA/KB-191HD5-B04I C — product datasheet (PDF)
- KA/KB-2x250CD1-B09 C — product datasheet (PDF)
- KA/KB-450BD1-B09 C — product datasheet (PDF)
- KA/KB-363BD1-B06I C — product datasheet (PDF)
- KA/KB-2x191FB5-B04 C — product datasheet (PDF)
- KA/KB-2x263AB5-B06I C — product datasheet (PDF)
- KA/KB-2x191FB5-B04I C — product datasheet (PDF)
- KA/KB-463AB5-B06I C — product datasheet (PDF)
- KA/KB-363BD1-B01 C — product datasheet (PDF)
- KA/KB-380AC5-B03 C — product datasheet (PDF)
- KA/KB-t-2x180EC5-B01 C — product datasheet (PDF)
- KA/KB-2x180GB5-B01 C — product datasheet (PDF)
- KA/KB-2x163GB1-B08 C — product datasheet (PDF)
- KA/KB-450CD1-B09 C — product datasheet (PDF)
- KA/KB-291FB5-B04 C — product datasheet (PDF)
- KA/KB-550AC1-B09 C — product datasheet (PDF)
- KA/KB-291FB5-B04I C — product datasheet (PDF)
- KA/KB-2x163GC1-B19 C — product datasheet (PDF)
- KA/KB-280GB5-B01 C — product datasheet (PDF)
- KA/KB-263GB1-B08 C — product datasheet (PDF)
- KA/KB-t-480EA1-B03 C — product datasheet (PDF)
- KA/KB-t-380EA1-B01 C — product datasheet (PDF)
- KA/KB-2x263AB5-B01 C — product datasheet (PDF)
- KA/KB-463AB5-B01 C — product datasheet (PDF)
- KA/KB-263GC1-B19 C — product datasheet (PDF)
- KA/KB-t-280EC5-B01 C — product datasheet (PDF)
- KA/KB-550AC1-B10 C — product datasheet (PDF)
- KA/KB-2x250CD1-B10 C — product datasheet (PDF)
- KA/KB-2x250BD1-B01I C — product datasheet (PDF)
- KA/KB-2x250CD1-B01I C — product datasheet (PDF)
- KA/KB-450BD1-B01I C — product datasheet (PDF)
- KA/KB-450CD1-B10 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.