- Catalogue
- Condensers
- KC-WF (W-type)
KC-WF (W-type)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 199.83–2250.34 kW
- Fans
- ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KC-WF-2x280BA5-B01C C | 199.83 kW | 4 × ⌀800 | 93,738 |
Variants (1) |
| KC-WF-2x280BA5-B01T C | 216.90 kW | 4 × ⌀800 | 95,035 |
Variants (1) |
| KC-WF-2x280BA1-B01C C | 227.79 kW | 4 × ⌀800 | 93,107 |
Variants (1) |
| KC-WF-2x291BA5-C04C C | 234.16 kW | 4 × ⌀910 | 128,300 |
Variants (1) |
| KC-WF-2x280AA5-B01C C | 234.40 kW | 4 × ⌀800 | 94,181 |
Variants (1) |
| KC-WF-2x280BA1-B01T C | 246.91 kW | 4 × ⌀800 | 94,534 |
Variants (1) |
| KC-WF-2x280AA1-B01C C | 258.32 kW | 4 × ⌀800 | 93,596 |
Variants (1) |
| KC-WF-2x291AA5-C04C C | 261.12 kW | 4 × ⌀910 | 127,433 |
Variants (1) |
| KC-WF-2x280AA5-B01T C | 261.88 kW | 4 × ⌀800 | 95,499 |
Variants (1) |
| KC-WF-2x280BB5-B01C C | 264.71 kW | 4 × ⌀800 | 90,774 |
Variants (1) |
| KC-WF-2x291BA1-C04C C | 268.24 kW | 4 × ⌀910 | 127,130 |
Variants (1) |
| KC-WF-2x291BA5-B04T C | 269.35 kW | 4 × ⌀910 | 131,093 |
Variants (1) |
| KC-WF-2x280BB5-B01T C | 286.19 kW | 4 × ⌀800 | 92,846 |
Variants (1) |
| KC-WF-2x280AA1-B01T C | 287.31 kW | 4 × ⌀800 | 95,040 |
Variants (1) |
| KC-WF-2x291AA1-C04C C | 289.92 kW | 4 × ⌀910 | 126,186 |
Variants (1) |
| KC-WF-2x291AA5-B04T C | 292.05 kW | 4 × ⌀910 | 130,801 |
Variants (1) |
| KC-WF-2x280BB1-B01C C | 294.60 kW | 4 × ⌀800 | 89,796 |
Variants (1) |
| KC-WF-2x280AB5-B01C C | 300.23 kW | 4 × ⌀800 | 91,477 |
Variants (1) |
| KC-WF-2x380BA5-B01C C | 300.99 kW | 6 × ⌀800 | 140,607 |
Variants (1) |
| KC-WF-2x291BA1-B04T C | 307.13 kW | 4 × ⌀910 | 130,236 |
Variants (1) |
| KC-WF-2x280BC5-B01C C | 317.79 kW | 4 × ⌀800 | 87,982 |
Variants (1) |
| KC-WF-2x280BB1-B01T C | 318.06 kW | 4 × ⌀800 | 92,041 |
Variants (1) |
| KC-WF-2x291BB5-C04C C | 322.72 kW | 4 × ⌀910 | 123,395 |
Variants (1) |
| KC-WF-2x291AA1-B04T C | 323.72 kW | 4 × ⌀910 | 129,899 |
Variants (1) |
| KC-WF-2x280AB1-B01C C | 323.92 kW | 4 × ⌀800 | 90,550 |
Variants (1) |
| KC-WF-2x380BA5-B01T C | 326.44 kW | 6 × ⌀800 | 142,552 |
Variants (1) |
| KC-WF-2x280AB5-B01T C | 333.33 kW | 4 × ⌀800 | 93,539 |
Variants (1) |
| KC-WF-2x280BC5-B01T C | 343.02 kW | 4 × ⌀800 | 90,534 |
Variants (1) |
| KC-WF-2x380BA1-B01C C | 343.19 kW | 6 × ⌀800 | 139,661 |
Variants (1) |
| KC-WF-2x280BC1-B01C C | 347.45 kW | 4 × ⌀800 | 86,794 |
Variants (1) |
| KC-WF-2x291AB5-C04C C | 352.25 kW | 4 × ⌀910 | 122,256 |
Variants (1) |
| KC-WF-2x291BB5-B04T C | 355.03 kW | 4 × ⌀910 | 127,245 |
Variants (1) |
| KC-WF-2x380AA5-B01C C | 355.65 kW | 6 × ⌀800 | 141,271 |
Variants (1) |
| KC-WF-2x280AB1-B01T C | 358.18 kW | 4 × ⌀800 | 92,855 |
Variants (1) |
| KC-WF-2x291BB1-C04C C | 361.71 kW | 4 × ⌀910 | 121,861 |
Variants (1) |
| KC-WF-2x391BA5-C04C C | 369.01 kW | 6 × ⌀910 | 192,450 |
Variants (1) |
| KC-WF-2x380BA1-B01T C | 371.69 kW | 6 × ⌀800 | 141,801 |
Variants (1) |
| KC-WF-2x280BC1-B01T C | 374.56 kW | 4 × ⌀800 | 89,537 |
Variants (1) |
| KC-WF-2x291AB5-B04T C | 377.46 kW | 4 × ⌀910 | 126,816 |
Variants (1) |
| KC-WF-2x480BA5-B01C C | 378.80 kW | 8 × ⌀800 | 187,476 |
Variants (1) |
| KC-WF-2x280BD5-B01T C | 381.05 kW | 4 × ⌀800 | 88,377 |
Variants (1) |
| KC-WF-2x291AB1-C04C C | 382.72 kW | 4 × ⌀910 | 120,637 |
Variants (1) |
| KC-WF-2x280AC5-B01T C | 387.28 kW | 4 × ⌀800 | 91,473 |
Variants (1) |
| KC-WF-2x291BC5-C04C C | 390.05 kW | 4 × ⌀910 | 118,826 |
Variants (1) |
| KC-WF-2x380BB5-B01C C | 391.38 kW | 6 × ⌀800 | 136,161 |
Variants (1) |
| KC-WF-2x380AA5-B01T C | 391.61 kW | 6 × ⌀800 | 143,249 |
Variants (1) |
| KC-WF-2x380AA1-B01C C | 391.81 kW | 6 × ⌀800 | 140,395 |
Variants (1) |
| KC-WF-2x391AA5-C04C C | 391.88 kW | 6 × ⌀910 | 191,149 |
Variants (1) |
| KC-WF-2x280BD1-B01T C | 395.21 kW | 4 × ⌀800 | 87,215 |
Variants (1) |
| KC-WF-2x291BB1-B04T C | 397.60 kW | 4 × ⌀910 | 125,991 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KC-WF-2x280BA5-B01C C — product datasheet (PDF)
- KC-WF-2x280BA5-B01T C — product datasheet (PDF)
- KC-WF-2x280BA1-B01C C — product datasheet (PDF)
- KC-WF-2x291BA5-C04C C — product datasheet (PDF)
- KC-WF-2x280AA5-B01C C — product datasheet (PDF)
- KC-WF-2x280BA1-B01T C — product datasheet (PDF)
- KC-WF-2x280AA1-B01C C — product datasheet (PDF)
- KC-WF-2x291AA5-C04C C — product datasheet (PDF)
- KC-WF-2x280AA5-B01T C — product datasheet (PDF)
- KC-WF-2x280BB5-B01C C — product datasheet (PDF)
- KC-WF-2x291BA1-C04C C — product datasheet (PDF)
- KC-WF-2x291BA5-B04T C — product datasheet (PDF)
- KC-WF-2x280BB5-B01T C — product datasheet (PDF)
- KC-WF-2x280AA1-B01T C — product datasheet (PDF)
- KC-WF-2x291AA1-C04C C — product datasheet (PDF)
- KC-WF-2x291AA5-B04T C — product datasheet (PDF)
- KC-WF-2x280BB1-B01C C — product datasheet (PDF)
- KC-WF-2x280AB5-B01C C — product datasheet (PDF)
- KC-WF-2x380BA5-B01C C — product datasheet (PDF)
- KC-WF-2x291BA1-B04T C — product datasheet (PDF)
- KC-WF-2x280BC5-B01C C — product datasheet (PDF)
- KC-WF-2x280BB1-B01T C — product datasheet (PDF)
- KC-WF-2x291BB5-C04C C — product datasheet (PDF)
- KC-WF-2x291AA1-B04T C — product datasheet (PDF)
- KC-WF-2x280AB1-B01C C — product datasheet (PDF)
- KC-WF-2x380BA5-B01T C — product datasheet (PDF)
- KC-WF-2x280AB5-B01T C — product datasheet (PDF)
- KC-WF-2x280BC5-B01T C — product datasheet (PDF)
- KC-WF-2x380BA1-B01C C — product datasheet (PDF)
- KC-WF-2x280BC1-B01C C — product datasheet (PDF)
- KC-WF-2x291AB5-C04C C — product datasheet (PDF)
- KC-WF-2x291BB5-B04T C — product datasheet (PDF)
- KC-WF-2x380AA5-B01C C — product datasheet (PDF)
- KC-WF-2x280AB1-B01T C — product datasheet (PDF)
- KC-WF-2x291BB1-C04C C — product datasheet (PDF)
- KC-WF-2x391BA5-C04C C — product datasheet (PDF)
- KC-WF-2x380BA1-B01T C — product datasheet (PDF)
- KC-WF-2x280BC1-B01T C — product datasheet (PDF)
- KC-WF-2x291AB5-B04T C — product datasheet (PDF)
- KC-WF-2x480BA5-B01C C — product datasheet (PDF)
- KC-WF-2x280BD5-B01T C — product datasheet (PDF)
- KC-WF-2x291AB1-C04C C — product datasheet (PDF)
- KC-WF-2x280AC5-B01T C — product datasheet (PDF)
- KC-WF-2x291BC5-C04C C — product datasheet (PDF)
- KC-WF-2x380BB5-B01C C — product datasheet (PDF)
- KC-WF-2x380AA5-B01T C — product datasheet (PDF)
- KC-WF-2x380AA1-B01C C — product datasheet (PDF)
- KC-WF-2x391AA5-C04C C — product datasheet (PDF)
- KC-WF-2x280BD1-B01T C — product datasheet (PDF)
- KC-WF-2x291BB1-B04T C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.