- Catalogue
- Condensers
- KC-WF (W-type)
KC-WF (W-type)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 199.83–2250.34 kW
- Fans
- ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KC-WF = KC-WF = W-type industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation BC = generation C
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)04 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
-
K
Delivery version (optional) — = absent: standardC = C: container delivery versionT = T: truck delivery version
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KC-WF-2x880AB1-B01C C | 1311.04 kW | 16 × ⌀800 | 362,199 |
Variants (1) |
| KC-WF-2x780AC5-B01T C | 1314.25 kW | 14 × ⌀800 | 320,154 |
Variants (1) |
| KC-WF-2x880AB5-B01T C | 1317.95 kW | 16 × ⌀800 | 374,154 |
Variants (1) |
| KC-WF-2x791AB1-C04C C | 1327.76 kW | 14 × ⌀910 | 422,228 |
Variants (1) |
| KC-WF-2x691AC5-B04T C | 1344.78 kW | 12 × ⌀910 | 369,466 |
Variants (1) |
| KC-WF-2x891AA1-B04T C | 1344.93 kW | 16 × ⌀910 | 519,597 |
Variants (1) |
| KC-WF-2x791AB5-B04T C | 1357.53 kW | 14 × ⌀910 | 443,855 |
Variants (1) |
| KC-WF-2x991AA1-C04C C | 1366.52 kW | 18 × ⌀910 | 567,839 |
Variants (1) |
| KC-WF-2x991AA5-B04T C | 1379.05 kW | 18 × ⌀910 | 588,603 |
Variants (1) |
| KC-WF-2x980AB5-B01C C | 1379.66 kW | 18 × ⌀800 | 411,647 |
Variants (1) |
| KC-WF-2x780AC1-B01T C | 1403.72 kW | 14 × ⌀800 | 316,907 |
Variants (1) |
| KC-WF-2x891AB5-C04C C | 1415.76 kW | 16 × ⌀910 | 489,024 |
Variants (1) |
| KC-WF-2x880AB1-B01T C | 1420.12 kW | 16 × ⌀800 | 371,418 |
Variants (1) |
| KC-WF-2x691AC1-B04T C | 1435.80 kW | 12 × ⌀910 | 364,789 |
Variants (1) |
| KC-WF-2x791AB1-B04T C | 1471.90 kW | 14 × ⌀910 | 439,325 |
Variants (1) |
| KC-WF-2x980AB1-B01C C | 1487.69 kW | 18 × ⌀800 | 407,474 |
Variants (1) |
| KC-WF-2x980AB5-B01T C | 1497.96 kW | 18 × ⌀800 | 420,923 |
Variants (1) |
| KC-WF-2x991AA1-B04T C | 1524.07 kW | 18 × ⌀910 | 584,546 |
Variants (1) |
| KC-WF-2x880AC5-B01T C | 1524.71 kW | 16 × ⌀800 | 365,890 |
Variants (1) |
| KC-WF-2x891AB1-C04C C | 1539.34 kW | 16 × ⌀910 | 482,547 |
Variants (1) |
| KC-WF-2x891AB5-B04T C | 1574.07 kW | 16 × ⌀910 | 507,263 |
Variants (1) |
| KC-WF-2x791AC5-B04T C | 1605.04 kW | 14 × ⌀910 | 431,043 |
Variants (1) |
| KC-WF-2x991AB5-C04C C | 1606.83 kW | 18 × ⌀910 | 550,152 |
Variants (1) |
| KC-WF-2x980AB1-B01T C | 1612.33 kW | 18 × ⌀800 | 417,845 |
Variants (1) |
| KC-WF-2x880AC1-B01T C | 1625.17 kW | 16 × ⌀800 | 362,180 |
Variants (1) |
| KC-WF-2x891AB1-B04T C | 1706.23 kW | 16 × ⌀910 | 502,085 |
Variants (1) |
| KC-WF-2x791AC1-B04T C | 1712.01 kW | 14 × ⌀910 | 425,588 |
Variants (1) |
| KC-WF-2x980AC5-B01T C | 1732.52 kW | 18 × ⌀800 | 411,627 |
Variants (1) |
| KC-WF-2x991AB1-C04C C | 1743.04 kW | 18 × ⌀910 | 542,865 |
Variants (1) |
| KC-WF-2x991AB5-B04T C | 1787.05 kW | 18 × ⌀910 | 570,670 |
Variants (1) |
| KC-WF-2x980AC1-B01T C | 1844.43 kW | 18 × ⌀800 | 407,452 |
Variants (1) |
| KC-WF-2x891AC5-B04T C | 1862.00 kW | 16 × ⌀910 | 492,621 |
Variants (1) |
| KC-WF-2x991AB1-B04T C | 1934.42 kW | 18 × ⌀910 | 564,846 |
Variants (1) |
| KC-WF-2x891AC1-B04T C | 1984.01 kW | 16 × ⌀910 | 486,386 |
Variants (1) |
| KC-WF-2x991AC5-B04T C | 2114.40 kW | 18 × ⌀910 | 554,199 |
Variants (1) |
| KC-WF-2x991AC1-B04T C | 2250.34 kW | 18 × ⌀910 | 547,184 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KC-WF-2x880AB1-B01C C — product datasheet (PDF)
- KC-WF-2x780AC5-B01T C — product datasheet (PDF)
- KC-WF-2x880AB5-B01T C — product datasheet (PDF)
- KC-WF-2x791AB1-C04C C — product datasheet (PDF)
- KC-WF-2x691AC5-B04T C — product datasheet (PDF)
- KC-WF-2x891AA1-B04T C — product datasheet (PDF)
- KC-WF-2x791AB5-B04T C — product datasheet (PDF)
- KC-WF-2x991AA1-C04C C — product datasheet (PDF)
- KC-WF-2x991AA5-B04T C — product datasheet (PDF)
- KC-WF-2x980AB5-B01C C — product datasheet (PDF)
- KC-WF-2x780AC1-B01T C — product datasheet (PDF)
- KC-WF-2x891AB5-C04C C — product datasheet (PDF)
- KC-WF-2x880AB1-B01T C — product datasheet (PDF)
- KC-WF-2x691AC1-B04T C — product datasheet (PDF)
- KC-WF-2x791AB1-B04T C — product datasheet (PDF)
- KC-WF-2x980AB1-B01C C — product datasheet (PDF)
- KC-WF-2x980AB5-B01T C — product datasheet (PDF)
- KC-WF-2x991AA1-B04T C — product datasheet (PDF)
- KC-WF-2x880AC5-B01T C — product datasheet (PDF)
- KC-WF-2x891AB1-C04C C — product datasheet (PDF)
- KC-WF-2x891AB5-B04T C — product datasheet (PDF)
- KC-WF-2x791AC5-B04T C — product datasheet (PDF)
- KC-WF-2x991AB5-C04C C — product datasheet (PDF)
- KC-WF-2x980AB1-B01T C — product datasheet (PDF)
- KC-WF-2x880AC1-B01T C — product datasheet (PDF)
- KC-WF-2x891AB1-B04T C — product datasheet (PDF)
- KC-WF-2x791AC1-B04T C — product datasheet (PDF)
- KC-WF-2x980AC5-B01T C — product datasheet (PDF)
- KC-WF-2x991AB1-C04C C — product datasheet (PDF)
- KC-WF-2x991AB5-B04T C — product datasheet (PDF)
- KC-WF-2x980AC1-B01T C — product datasheet (PDF)
- KC-WF-2x891AC5-B04T C — product datasheet (PDF)
- KC-WF-2x991AB1-B04T C — product datasheet (PDF)
- KC-WF-2x891AC1-B04T C — product datasheet (PDF)
- KC-WF-2x991AC5-B04T C — product datasheet (PDF)
- KC-WF-2x991AC1-B04T C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.