Skip to Content

KT (Commercial)

Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
Capacity
0.48–270.69 kW
Fans
⌀170, ⌀200, ⌀230, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450, ⌀500, ⌀630 mm
Max. working pressure
27 bar
KT (Commercial)
Model Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % Fans Air flow [m³/h] Variants
KT-250AC2-B08 C 23.74 kW 2 × ⌀500 7,638
Variants (1)
KT-t-245GC3-B04 C 23.75 kW 2 × ⌀450 5,548
Variants (1)
KT-150GC1-B09 C 23.80 kW 1 × ⌀500 6,502
Variants (1)
KT-245BC2-B04 C 23.84 kW 2 × ⌀450 7,091
Variants (1)
KT-t-335CB1-B01 C 23.85 kW 3 × ⌀350 6,977
Variants (1)
KT-335CC1-B01 C 23.92 kW 3 × ⌀350 6,825
Variants (1)
KT-t-145HC2-B01 C 23.92 kW 1 × ⌀450 5,565
Variants (1)
KT-245AD1-B04 C 23.94 kW 2 × ⌀450 5,458
Variants (1)
KT-240DC1-B01 C 24.01 kW 2 × ⌀400 6,619
Variants (1)
KT-2x235CC1-B02 C 24.17 kW 4 × ⌀350 5,903
Variants (1)
KT-t-150CC1-B09 C 24.25 kW 1 × ⌀500 6,151
Variants (1)
KT-t-145EC1-B01 C 24.34 kW 1 × ⌀450 5,603
Variants (1)
KT-t-240BC1-B01 C 24.40 kW 2 × ⌀400 5,726
Variants (1)
KT-250ED3-B04 C 24.52 kW 2 × ⌀500 6,405
Variants (1)
KT-t-245AC1-B04 C 24.54 kW 2 × ⌀450 5,479
Variants (1)
KT-245GC2-B04 C 24.55 kW 2 × ⌀450 6,636
Variants (1)
KT-250AC2-B04 C 24.60 kW 2 × ⌀500 8,061
Variants (1)
KT-150GD2-B09 C 24.63 kW 1 × ⌀500 6,328
Variants (1)
KT-340CB2-B01 C 24.64 kW 3 × ⌀400 10,096
Variants (1)
KT-245CC1-B04 C 24.66 kW 2 × ⌀450 6,510
Variants (1)
KT-245EC3-B01 C 24.73 kW 2 × ⌀450 8,593
Variants (1)
KT-150EC1-B09 C 24.75 kW 1 × ⌀500 7,081
Variants (1)
KT-t-240CC1-B01 C 24.76 kW 2 × ⌀400 5,726
Variants (1)
KT-245AC2-B01 C 24.99 kW 2 × ⌀450 9,393
Variants (1)
KT-t-150GC2-B09 C 25.20 kW 1 × ⌀500 6,340
Variants (1)
KT-250BB1-B04 C 25.23 kW 2 × ⌀500 9,180
Variants (1)
KT-t-2x235CC2-B02 C 25.37 kW 4 × ⌀350 5,686
Variants (1)
KT-t-335CC2-B01 C 25.39 kW 3 × ⌀350 6,590
Variants (1)
KT-340CC1-B03 C 25.52 kW 3 × ⌀400 6,367
Variants (1)
KT-t-245FC2-B04 C 25.68 kW 2 × ⌀450 5,764
Variants (1)
KT-245BC1-B04 C 25.72 kW 2 × ⌀450 6,757
Variants (1)
KT-t-245AB1-B03 C 25.83 kW 2 × ⌀450 8,192
Variants (1)
KT-t-340CB1-B03 C 25.84 kW 3 × ⌀400 6,520
Variants (1)
KT-t-240DC2-B01 C 25.89 kW 2 × ⌀400 6,465
Variants (1)
KT-245AC1-B03 C 25.90 kW 2 × ⌀450 8,015
Variants (1)
KT-250BB2-B09 C 26.05 kW 2 × ⌀500 13,041
Variants (1)
KT-345BB2-B04 C 26.09 kW 3 × ⌀450 10,379
Variants (1)
KT-t-245CC2-B04 C 26.14 kW 2 × ⌀450 6,288
Variants (1)
KT-250AC1-B08 C 26.25 kW 2 × ⌀500 7,371
Variants (1)
KT-245CC2-B03 C 26.33 kW 2 × ⌀450 8,916
Variants (1)
KT-340CB1-B01 C 26.54 kW 3 × ⌀400 9,887
Variants (1)
KT-250FD3-B08 C 26.54 kW 2 × ⌀500 6,679
Variants (1)
KT-150GD1-B09 C 26.57 kW 1 × ⌀500 6,158
Variants (1)
KT-245GC1-B04 C 26.58 kW 2 × ⌀450 6,423
Variants (1)
KT-245AD2-B03 C 26.60 kW 2 × ⌀450 7,722
Variants (1)
KT-2x330FB2-B01 C 26.67 kW 6 × ⌀300 8,798
Variants (1)
KT-t-150EC2-B09 C 26.74 kW 1 × ⌀500 6,968
Variants (1)
KT-t-250BB2-B04 C 26.88 kW 2 × ⌀500 8,935
Variants (1)
KT-t-340CC2-B03 C 26.99 kW 3 × ⌀400 6,132
Variants (1)
KT-t-250ED3-B04 C 27.05 kW 2 × ⌀500 5,772
Variants (1)

Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.