Skip to Content

KT (Commercial)

Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
Capacity
0.48–270.69 kW
Fans
⌀170, ⌀200, ⌀230, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450, ⌀500, ⌀630 mm
Max. working pressure
27 bar
KT (Commercial)
Model Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % Fans Air flow [m³/h] Variants
KT-350FC2-B04 C 40.84 kW 3 × ⌀500 11,596
Variants (1)
KT-2x335CB1-B01 C 40.93 kW 6 × ⌀350 14,840
Variants (1)
KT-2x245EA1-B04 C 41.02 kW 4 × ⌀450 17,025
Variants (1)
KT-t-263AB2-B03 C 41.32 kW 2 × ⌀630 8,927
Variants (1)
KT-250HC1-B04 C 41.39 kW 2 × ⌀500 9,619
Variants (1)
KT-263AC1-B03 C 41.60 kW 2 × ⌀630 8,648
Variants (1)
KT-t-350FD3-B04 C 41.63 kW 3 × ⌀500 8,938
Variants (1)
KT-2x340EB1-B03 C 41.65 kW 6 × ⌀400 12,221
Variants (1)
KT-t-250DC2-B04 C 41.69 kW 2 × ⌀500 9,677
Variants (1)
KT-250GC2-B09 C 41.86 kW 2 × ⌀500 13,000
Variants (1)
KT-250HD2-B04 C 41.90 kW 2 × ⌀500 9,404
Variants (1)
KT-263AC2-B03 C 41.94 kW 2 × ⌀630 8,818
Variants (1)
KT-t-250HC2-B08 C 42.18 kW 2 × ⌀500 9,067
Variants (1)
KT-350FC1-B08 C 42.25 kW 3 × ⌀500 10,601
Variants (1)
KT-t-345BB1-B01 C 42.40 kW 3 × ⌀450 14,400
Variants (1)
KT-t-2x335CB2-B01 C 42.62 kW 6 × ⌀350 14,384
Variants (1)
KT-250GC2-B10 C 42.65 kW 2 × ⌀500 13,402
Variants (1)
KT-2x240CC1-B01 C 42.96 kW 4 × ⌀400 12,310
Variants (1)
KT-250CC1-B09 C 43.04 kW 2 × ⌀500 13,286
Variants (1)
KT-t-2x340EB2-B03 C 43.06 kW 6 × ⌀400 11,722
Variants (1)
KT-t-250BD4-B09 C 43.11 kW 2 × ⌀500 11,441
Variants (1)
KT-t-250DC1-B04 C 43.14 kW 2 × ⌀500 9,489
Variants (1)
KT-245HC1-B01 C 43.40 kW 2 × ⌀450 11,127
Variants (1)
KT-250HD1-B04 C 43.46 kW 2 × ⌀500 9,202
Variants (1)
KT-250DD1-B04 C 43.55 kW 2 × ⌀500 9,474
Variants (1)
KT-2x245GB2-B04 C 43.68 kW 4 × ⌀450 14,479
Variants (1)
KT-t-250HC2-B04 C 43.74 kW 2 × ⌀500 9,420
Variants (1)
KT-350FC1-B04 C 43.76 kW 3 × ⌀500 11,132
Variants (1)
KT-345BD3-B01 C 43.81 kW 3 × ⌀450 13,825
Variants (1)
KT-t-250BC1-B09 C 43.87 kW 2 × ⌀500 11,480
Variants (1)
KT-2x340EC2-B03 C 43.98 kW 6 × ⌀400 11,389
Variants (1)
KT-2x245EA2-B01 C 43.98 kW 4 × ⌀450 25,444
Variants (1)
KT-t-2x245EA2-B04 C 44.09 kW 4 × ⌀450 16,781
Variants (1)
KT-345BC1-B01 C 44.13 kW 3 × ⌀450 14,070
Variants (1)
KT-t-350FC2-B08 C 44.72 kW 3 × ⌀500 10,165
Variants (1)
KT-345BD2-B01 C 45.08 kW 3 × ⌀450 13,526
Variants (1)
KT-t-250GB1-B09 C 45.17 kW 2 × ⌀500 12,897
Variants (1)
KT-250GC1-B09 C 45.68 kW 2 × ⌀500 12,676
Variants (1)
KT-t-2x240CC2-B01 C 45.68 kW 4 × ⌀400 11,868
Variants (1)
KT-t-345BC3-B01 C 45.70 kW 3 × ⌀450 13,766
Variants (1)
KT-350HC2-B08 C 45.85 kW 3 × ⌀500 12,514
Variants (1)
KT-2x245GB1-B04 C 45.96 kW 4 × ⌀450 14,070
Variants (1)
KT-t-245HC2-B01 C 45.98 kW 2 × ⌀450 10,881
Variants (1)
KT-t-350FC2-B04 C 46.29 kW 3 × ⌀500 10,673
Variants (1)
KT-t-250CC2-B09 C 46.32 kW 2 × ⌀500 12,962
Variants (1)
KT-2x340EC1-B03 C 46.87 kW 6 × ⌀400 10,903
Variants (1)
KT-t-2x340EB1-B03 C 46.95 kW 6 × ⌀400 11,230
Variants (1)
KT-t-345BC2-B01 C 47.02 kW 3 × ⌀450 13,563
Variants (1)
KT-2x340EB2-B01 C 47.36 kW 6 × ⌀400 18,383
Variants (1)
KT-350HC2-B04 C 47.43 kW 3 × ⌀500 13,126
Variants (1)

Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.