Dry cooler BC/BD-2x391LD1-B04 C

Dry cooler BC/BD-2x391LD1-B04 C
Illustrative photo

Producer: Karyer · Line: BC/BD (General)

Product code: BC/BD-2x391LD1-B04 C

Heat rejection i
484.03 kW
Air flow
140,427 m³/h
Fans
6 × ⌀910 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Data

Coil
Air flow 140,427 m³/h
External surface 1,339.5 m²
Inner volume 191.8 dm³
Fin materialAluminium
Net weight 1,174 kg
Fans
Quantity 6
Diameter 910 mm
Speed 840 rpm
Power 16,800 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 67.0 dB(A)
Sound power 99.3 dB(A)
Energy class E
Connections
Inlet 5"
Outlet 5"
Defrost
BC/BD-2x391LD1-B04 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
484.026 kW Fluid flow 84.01 m³/h Pressure drop 80.6 kPa above the recommended pressure drop
Heat rejection · Low speed (Y)
not rated

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 284.42 not rated not rated not rated not rated not rated
40 484.03 285.31 not rated not rated not rated not rated
45 678.55 483.69 286.13 not rated not rated not rated
50 871.33 677.16 483.53 286.99 not rated not rated
55 1063.43 868.93 676.04 483.66 287.99 not rated
60 1255.06 1060.01 867.06 675.54 484.19 289.19

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 not rated not rated not rated not rated not rated not rated
40 not rated not rated not rated not rated not rated not rated
45 not rated not rated not rated not rated not rated not rated
50 not rated not rated not rated not rated not rated not rated
55 not rated not rated not rated not rated 221.94 not rated
60 not rated not rated not rated not rated 369.34 222.99

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 484.026 84.01 80.6
Low speed (Y) — — —

Dimensions

Dimension drawing of BC/BD-2x391LD1-B04 C
Dimension drawing
Dimensions as drawn
A 5800 mm
B 1450 mm
C 2310 mm
F 1150 mm
G 550 mm
E 5350 mm
H 1750 mm
I 2260 mm
K 6300 mm
D IN 5"
D OUT 5"
Overall [mm]
Length 6300 mm
Width 2310 mm
Height 1450 mm

Downloads