BC/BD-2X150DC1-B09 C
40.59 kW
Defrost: None
Product code: BC/BD-t-180JC5-B03 C
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Air flow | 9,367 m³/h |
|---|---|
| External surface | 153.3 m² |
| Inner volume | 19.8 dm³ |
| Fin material | Aluminium |
| Net weight | 225 kg |
| Quantity | 1 |
|---|---|
| Diameter | 800 mm |
| Speed | 435 rpm |
| Power | 300 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 12 |
| Sound pressure | 32.0 dB(A) |
|---|---|
| Sound power | 64.0 dB(A) |
| Energy class | B |
| Inlet | 1 1/4" |
|---|---|
| Outlet | 1 1/4" |
| BC/BD-t-180JC5-B03 C | None |
|---|
Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.
WATER 40 → 35 °C, air inlet 25 °C
WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 24.70 | not rated | not rated | not rated | not rated | not rated |
| 40 | 40.60 | 24.70 | not rated | not rated | not rated | not rated |
| 45 | 55.94 | 40.43 | 24.70 | not rated | not rated | not rated |
| 50 | 71.10 | 55.64 | 40.30 | 24.71 | not rated | not rated |
| 55 | 86.18 | 70.68 | 55.39 | 40.20 | 24.75 | not rated |
| 60 | 101.22 | 85.63 | 70.32 | 55.21 | 40.17 | 24.81 |
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 18.87 | not rated | not rated | not rated | not rated | not rated |
| 40 | 30.68 | 18.86 | not rated | not rated | not rated | not rated |
| 45 | 42.05 | 30.54 | 18.85 | not rated | not rated | not rated |
| 50 | 53.28 | 41.80 | 30.42 | 18.86 | not rated | not rated |
| 55 | 64.44 | 52.93 | 41.60 | 30.34 | 18.88 | not rated |
| 60 | 75.57 | 64.00 | 52.65 | 41.45 | 30.30 | 18.93 |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Fan connection | Heat rejection [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 40.598 | 7.04 | 39.2 |
| Low speed (Y) | 30.680 | 5.32 | 23.7 |
| A | 2100 mm |
|---|---|
| B | 1450 mm |
| C | 1230 mm |
| F | 1150 mm |
| G | 550 mm |
| E | 1850 mm |
| H | 1750 mm |
| I | 1180 mm |
| K | 2400 mm |
| D IN | 1 1/4" |
| D OUT | 1 1/4" |
| Length | 2400 mm |
|---|---|
| Width | 1230 mm |
| Height | 1450 mm |