Dry cooler BE-491AD5-B04 C

Dry cooler BE-491AD5-B04 C
Illustrative photo

Producer: Karyer · Line: BE (Dry)

Product code: BE-491AD5-B04 C

Heat rejection i
401.42 kW
Air flow
108,242 m³/h
Fans
4 × ⌀910 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: BE — BE = V-type dry cooler.
  • D
    Number of fans per row: 4 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 91 — Ø910 mm
  • G
    Coil tube rows (2nd dimensional letter): D — 5 tube rows
  • H
    Fin spacing: 5 — 2.5 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 04 — three-phase 400 V 50 Hz, 6-pole AC fan (in this series)

Data

Coil
Air flow 108,242 m³/h
External surface 1,591.9 m²
Inner volume 229.1 dm³
Fin materialAluminium
Net weight 1,300 kg
Fans
Quantity 4
Diameter 910 mm
Speed 840 rpm
Power 11,200 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 64.0 dB(A)
Sound power 96.0 dB(A)
Energy class D
Connections
Inlet 3"
Outlet 3"
Defrost
BE-491AD5-B04 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
401.422 kW Fluid flow 69.62 m³/h Pressure drop 101.4 kPa above the recommended pressure drop
Heat rejection · Low speed (Y)
314.114 kW Fluid flow 54.48 m³/h Pressure drop 65.6 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 240.30 not rated not rated not rated not rated not rated
40 401.42 240.15 not rated not rated not rated not rated
45 558.54 400.00 240.00 not rated not rated not rated
50 714.31 555.94 398.77 239.93 not rated not rated
55 869.46 710.59 553.72 397.84 240.05 not rated
60 1024.27 864.63 707.39 552.00 397.33 240.41

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 189.93 not rated not rated not rated not rated not rated
40 314.11 189.79 not rated not rated not rated not rated
45 434.94 312.97 189.63 not rated not rated not rated
50 554.63 432.88 312.02 189.62 not rated not rated
55 673.81 551.71 431.17 311.34 189.76 not rated
60 792.70 670.04 549.27 429.90 311.03 190.12

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 401.422 69.62 101.4
Low speed (Y) 314.114 54.48 65.6

Dimensions

Dimension drawing of BE-491AD5-B04 C
Dimension drawing
Dimensions as drawn
A 1958 mm
B 1210 mm
C 5260 mm
F 1050 mm
G 5860 mm
E1 1230 mm
E2 1200 mm
D IN 3"
D OUT 3"
Overall [mm]
Length 5860 mm
Width 1210 mm
Height 1958 mm

Downloads