Skip to Content

Dry cooler BE-t-380GB1-B01 C

Dry cooler BE-t-380GB1-B01 C
Illustrative photo

Producer: Karyer · Line: BE (Dry)

Product code: BE-t-380GB1-B01 C

Heat rejection i
232.28 kW
Air flow
63,019 m³/h
Fans
3 × ⌀800 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: BE — BE = V-type dry cooler.
  • B
    Fin type (optional "t"): t — t: louvered fins (high-efficiency fin surface)
  • D
    Number of fans per row: 3 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 80 — Ø800 mm
  • G
    Coil tube rows (2nd dimensional letter): B — 3 tube rows
  • H
    Fin spacing: 1 — 2.1 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 01 — three-phase 400 V 50 Hz, 6-pole AC fan (in this series)

Data

Coil
Air flow 63,019 m³/h
External surface 581.7 m²
Inner volume 81.8 dm³
Fin materialAluminium
Net weight 771 kg
Fans
Quantity 3
Diameter 800 mm
Speed 900 rpm
Power 5,400 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 53.0 dB(A)
Sound power 85.0 dB(A)
Energy class D
Connections
Inlet 2 1/2"
Outlet 2 1/2"
Defrost
BE-t-380GB1-B01 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
232.279 kW Fluid flow 40.32 m³/h Pressure drop 67.0 kPa
Heat rejection · Low speed (Y)
181.341 kW Fluid flow 31.45 m³/h Pressure drop 43.1 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 137.11 not rated not rated not rated not rated not rated
40 232.28 137.27 not rated not rated not rated not rated
45 324.77 231.56 137.39 not rated not rated not rated
50 416.40 323.32 230.96 137.54 not rated not rated
55 507.63 414.24 322.08 230.52 137.74 not rated
60 598.63 504.76 412.38 321.11 230.29 138.06

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 108.15 not rated not rated not rated not rated not rated
40 181.34 108.21 not rated not rated not rated not rated
45 252.29 180.66 108.24 not rated not rated not rated
50 322.48 250.97 180.08 108.27 not rated not rated
55 392.32 320.56 249.84 179.64 108.40 not rated
60 461.97 389.81 318.91 248.96 179.39 108.63

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 232.279 40.32 67.0
Low speed (Y) 181.341 31.45 43.1

Dimensions

Dimension drawing of BE-t-380GB1-B01 C
Dimension drawing
Dimensions as drawn
A 1808 mm
B 1210 mm
C 3760 mm
F 1050 mm
G 4360 mm
E1 1130 mm
E2 1100 mm
D IN 2 1/2"
D OUT 2 1/2"
Overall [mm]
Length 4360 mm
Width 1210 mm
Height 1808 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.