Skip to Content

Compressor rack BSCR-2P-4CES-6Y

Illustrative photo

Producer: Albassem BRI · Line: Sphinx CompactRack MT

Product code: BSCR-2P-4CES-6Y

Refrigerating capacity i
32.00 kW
Absorbed power
15.00 kW
COP
2.13
Compressors
2 × semi-hermetic reciprocating compressors
Receiver
60 l

Nominal conditions: evaporating -10 °C, condensing 45 °C (dew points), superheat 10 K, subcooling 3 K; refrigerant R404A where rated.

Data

Rack
ApplicationMedium temperature (MT)
Compressors2 × semi-hermetic reciprocating compressors
Liquid receiver 60 l
Net weight 390 kg
Electrical
Max. current 32.0 A
Starting current 98.0 A
Connections
Suction 1"5/8
Liquid 7/8"
Discharge 1"1/8
Liquid set
L / W / H 666/402/1366 mm
Weight 80 kg

Performance

Evaporating temperature -50…5 °C, condensing temperature 20…55 °C (dew points); superheat 10 K, subcooling 3 K.

R404A, evaporating -10 °C, condensing 45 °C (dew points; superheat 10 K, subcooling 3 K)

Refrigerating capacity
32.00 kW
Absorbed power
15.00 kW
COP
2.13
Current
25.9 A
Heat rejection
47.00 kW

Heat rejection = refrigerating capacity + absorbed power. COP = refrigerating capacity / absorbed power.

Standard points

Te [°C] Tc [°C] Refrigerating capacity [kW] Absorbed power [kW] COP Current [A]
-10 40 35.50 14.30 2.48 24.8
-10 45 32.00 15.00 2.13 25.9

Evaporating × condensing temperature (dew points)

R404A; rows: condensing temperature Tc [°C]; columns: evaporating temperature Te [°C]. The highlighted cell is the nominal point. "—": outside the compressors' operating envelope.

Capacity [kW]

Capacity [kW]: Evaporating × condensing temperature (dew points)
Tc \ Te [°C] -40-35-30-25-20-15-10-50
20 11.20 15.00 19.80 25.40 32.20 40.10 49.50 60.40 73.20
25 10.00 13.60 17.90 23.20 29.60 37.10 46.00 56.40 68.70
30 8.80 12.10 16.20 21.10 27.00 34.10 42.50 52.40 64.10
35 7.70 10.70 14.40 19.00 24.50 31.10 39.00 48.40 59.40
40 6.60 9.30 12.70 16.90 22.00 28.10 35.50 44.30 54.60
45 5.50 8.00 11.00 14.90 19.50 25.20 32.00 40.20 49.80
50 4.60 6.70 9.40 12.90 17.10 22.30 28.60 36.10 45.00
55 3.70 5.50 7.90 10.90 14.70 19.40 25.00 31.90 not rated

Power [kW]

Power [kW]: Evaporating × condensing temperature (dew points)
Tc \ Te [°C] -40-35-30-25-20-15-10-50
20 6.10 7.10 8.00 8.80 9.50 10.10 10.60 10.80 10.70
25 6.30 7.30 8.30 9.30 10.20 11.00 11.60 12.00 12.20
30 6.30 7.50 8.60 9.70 10.80 11.80 12.60 13.20 13.60
35 6.40 7.60 8.90 10.10 11.30 12.50 13.50 14.30 15.00
40 6.40 7.70 9.10 10.40 11.80 13.10 14.30 15.30 16.20
45 6.40 7.80 9.20 10.70 12.20 13.60 15.00 16.30 17.30
50 6.30 7.80 9.30 10.90 12.50 14.10 15.70 17.10 18.40
55 6.30 7.80 9.40 11.10 12.80 14.60 16.20 17.80 not rated

COP

COP: Evaporating × condensing temperature (dew points)
Tc \ Te [°C] -40-35-30-25-20-15-10-50
20 1.84 2.11 2.48 2.89 3.39 3.97 4.67 5.59 6.84
25 1.59 1.86 2.16 2.49 2.90 3.37 3.97 4.70 5.63
30 1.40 1.61 1.88 2.18 2.50 2.89 3.37 3.97 4.71
35 1.20 1.41 1.62 1.88 2.17 2.49 2.89 3.38 3.96
40 1.03 1.21 1.40 1.62 1.86 2.15 2.48 2.90 3.37
45 0.86 1.03 1.20 1.39 1.60 1.85 2.13 2.47 2.88
50 0.73 0.86 1.01 1.18 1.37 1.58 1.82 2.11 2.45
55 0.59 0.71 0.84 0.98 1.15 1.33 1.54 1.79 not rated

Dimensions

Overall [mm]
Length 1320 mm
Width 825 mm
Height 1255 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.