EA-DI-363GE7-A13 C
81.03 kW
Defrost: None
Product code: EA-DI-363GG10-A13 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 53,193 m³/h |
|---|---|
| External surface | 316.6 m² |
| Inner volume | 127.7 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 691 kg |
| Quantity | 3 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 8,100 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 69.0 dB(A) |
|---|---|
| Sound power | 93.0 dB(A) |
| Energy class | D |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EA-DI-363GG10-A13 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 34.24 | 34.21 | 34.35 | 34.47 | 34.32 | 34.00 | 33.57 | 33.57 | 35.51 | 38.25 | 37.07 | 36.62 | 35.97 | 34.99 |
| 5 | 43.31 | 44.19 | 44.94 | 45.54 | 45.69 | 45.47 | 45.08 | 45.07 | 47.67 | 51.38 | 49.77 | 49.17 | 48.32 | 47.01 |
| 6 | 51.76 | 53.66 | 55.28 | 56.34 | 57.04 | 57.25 | 57.07 | 57.15 | 60.48 | 65.28 | 63.27 | 62.51 | 61.39 | 59.60 |
| 7 | 59.52 | 62.06 | 64.64 | 66.91 | 68.41 | 69.13 | 69.29 | 69.58 | 73.72 | 79.71 | 77.46 | 76.55 | 75.21 | 73.01 |
| 8 | 65.78 | 69.67 | 73.20 | 76.29 | 78.42 | 79.78 | 80.54 | 81.32 | 86.35 | 93.73 | 91.65 | 90.79 | 89.39 | 86.84 |
| 9 | 71.77 | 76.79 | 81.37 | 85.40 | 88.26 | 90.13 | 91.28 | 92.33 | 98.09 | 106.53 | 104.31 | 103.35 | 101.90 | 99.42 |
| 10 | ≈ 77.19 | 83.42 | 89.15 | 94.21 | 97.84 | 100.37 | 101.95 | 103.33 | 109.86 | 119.39 | 117.05 | 116.01 | 114.41 | 111.65 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 29.62 | 29.50 | 29.47 | 29.50 | 29.34 | 29.07 | 28.73 | 28.85 | 30.56 | 32.97 | 32.05 | 31.72 | 31.24 | 30.46 |
| 5 | 37.74 | 38.08 | 38.41 | 38.66 | 38.68 | 38.48 | 38.11 | 38.18 | 40.41 | 43.59 | 42.27 | 41.79 | 41.10 | 40.06 |
| 6 | 45.36 | 46.38 | 47.29 | 48.07 | 48.38 | 48.34 | 47.99 | 48.06 | 50.86 | 54.89 | 53.19 | 52.55 | 51.60 | 50.08 |
| 7 | 52.48 | 54.34 | 55.99 | 57.13 | 57.90 | 58.18 | 58.06 | 58.20 | 61.62 | 66.57 | 64.54 | 63.72 | 62.51 | 60.54 |
| 8 | 59.06 | 61.51 | 63.94 | 66.11 | 67.44 | 68.11 | 68.25 | 68.55 | 72.62 | 78.54 | 76.26 | 75.31 | 73.87 | 71.48 |
| 9 | 64.53 | 68.08 | 71.31 | 74.16 | 76.07 | 77.28 | 77.92 | 78.65 | 83.48 | 90.54 | 88.13 | 87.05 | 85.43 | 82.68 |
| 10 | 69.74 | 74.26 | 78.38 | 81.96 | 84.48 | 86.12 | 87.04 | 87.99 | 93.43 | 101.35 | 99.03 | 97.99 | 96.40 | 93.67 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 117.047 | 99.028 |
| SC2 | 0 | 8 | 81.317 | 68.549 |
| SC3 | -18 | 7 | 67.589 | 57.501 |
| SC4 | -25 | 6 | 55.282 | 47.290 |
| SC5 | -34 | 6 | 52.240 | 45.641 |
| A | 4325 mm |
|---|---|
| B | 1100 mm |
| C | 1150 mm |
| F | 1060 mm |
| G | 1640 mm |
| E1 | 1318 mm |
| E2 | 1300 mm |
| E | 3935 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 4325 mm |
|---|---|
| Width | 1640 mm |
| Height | 1150 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.