EA-DI-491GE4-A04 C
158.91 kW
Defrost: None
Product code: EA-DI-491GG7-A04 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 91,865 m³/h |
|---|---|
| External surface | 703.0 m² |
| Inner volume | 204.4 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 1,254 kg |
| Quantity | 4 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 11,200 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 73.0 dB(A) |
|---|---|
| Sound power | 97.5 dB(A) |
| Energy class | D |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø66,7 |
| EA-DI-491GG7-A04 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 68.69 | 69.13 | 69.39 | 69.83 | 69.66 | 69.08 | 68.19 | 69.52 | 73.96 | 80.01 | 78.01 | 77.22 | 76.09 | 74.35 |
| 5 | 86.57 | 88.61 | 90.35 | 91.72 | 92.09 | 91.68 | 90.60 | 91.80 | 97.28 | 105.16 | 102.13 | 101.08 | 99.61 | 97.49 |
| 6 | 103.26 | 106.72 | 110.21 | 113.08 | 114.50 | 114.74 | 113.99 | 115.14 | 122.07 | 131.95 | 127.85 | 126.30 | 124.00 | 120.46 |
| 7 | 117.33 | 123.13 | 128.38 | 132.94 | 135.80 | 137.29 | 137.62 | 139.35 | 147.74 | 159.88 | 154.95 | 153.00 | 150.09 | 145.35 |
| 8 | 130.24 | 138.16 | 145.32 | 151.50 | 155.59 | 157.90 | 158.73 | 160.68 | 170.59 | 185.16 | 180.34 | 178.38 | 175.40 | 170.37 |
| 9 | 142.03 | 152.23 | 161.50 | 169.55 | 175.07 | 178.29 | 179.76 | 182.14 | 193.39 | 209.87 | 204.60 | 202.31 | 198.83 | 192.73 |
| 10 | ≈ 152.73 | 165.31 | 176.89 | 187.00 | 193.99 | 198.50 | 200.73 | 203.65 | 216.30 | 234.74 | 229.09 | 226.51 | 222.52 | 215.44 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | 56.62 | 60.36 | 65.46 | 64.06 | 63.63 | 63.06 | 62.11 |
| 5 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 6 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 7 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 8 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 9 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 10 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 229.094 | — |
| SC2 | 0 | 8 | 160.683 | — |
| SC3 | -18 | 7 | 134.267 | — |
| SC4 | -25 | 6 | 110.209 | — |
| SC5 | -34 | 6 | 104.277 | — |
| A | 5625 mm |
|---|---|
| B | 1100 mm |
| C | 1350 mm |
| F | 1060 mm |
| G | 1900 mm |
| E1 | 1318 mm |
| E2 | 1300 mm |
| E | 5235 mm |
| D IN | 2 x Ø35 |
| D OUT | 2 x Ø66,7 |
| Length | 5625 mm |
|---|---|
| Width | 1900 mm |
| Height | 1350 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.