EA-430AC8-C05 C
7.13 kW
Defrost: None
Product code: EA-150AC10-C10 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 7,472 m³/h |
|---|---|
| Air throw | 20 m |
| External surface | 15.8 m² |
| Inner volume | 7.5 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 54 kg |
| Quantity | 1 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,360 rpm |
| Power | 690 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 58.0 dB(A) |
|---|---|
| Sound power | 80.2 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EA-150AC10-C10 C | None |
|---|---|
| EA-150AC10-C10 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.80 | 2.76 | 2.73 | 2.71 | 2.66 | 2.61 | 2.55 | 2.54 | 2.67 | 2.86 | 2.75 | 2.71 | 2.66 | 2.57 |
| 5 | 3.69 | 3.71 | 3.73 | 3.74 | 3.72 | 3.67 | 3.61 | 3.60 | 3.80 | 4.08 | 3.93 | 3.88 | 3.80 | 3.68 |
| 6 | 4.57 | 4.67 | 4.76 | 4.82 | 4.84 | 4.83 | 4.78 | 4.78 | 5.05 | 5.43 | 5.24 | 5.17 | 5.07 | 4.91 |
| 7 | 5.37 | 5.56 | 5.74 | 5.90 | 5.99 | 6.02 | 5.99 | 6.01 | 6.36 | 6.86 | 6.65 | 6.56 | 6.43 | 6.23 |
| 8 | 6.04 | 6.32 | 6.58 | 6.81 | 6.94 | 7.04 | 7.10 | 7.17 | 7.62 | 8.27 | 8.09 | 8.01 | 7.87 | 7.64 |
| 9 | 6.66 | 7.04 | 7.35 | 7.66 | 7.88 | 8.03 | 8.12 | 8.22 | 8.73 | 9.49 | 9.29 | 9.21 | 9.09 | 8.88 |
| 10 | 7.23 | 7.68 | 8.12 | 8.52 | 8.81 | 9.01 | 9.14 | 9.26 | 9.85 | 10.71 | 10.51 | 10.42 | 10.28 | 10.05 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.50 | 2.46 | 2.43 | 2.40 | 2.37 | 2.33 | 2.28 | 2.29 | 2.41 | 2.59 | 2.50 | 2.47 | 2.42 | 2.35 |
| 5 | 3.30 | 3.30 | 3.30 | 3.30 | 3.27 | 3.23 | 3.18 | 3.18 | 3.36 | 3.62 | 3.50 | 3.45 | 3.39 | 3.30 |
| 6 | 4.07 | 4.13 | 4.19 | 4.23 | 4.24 | 4.21 | 4.17 | 4.17 | 4.41 | 4.75 | 4.58 | 4.52 | 4.44 | 4.31 |
| 7 | 4.83 | 4.96 | 5.08 | 5.19 | 5.23 | 5.23 | 5.20 | 5.22 | 5.52 | 5.95 | 5.76 | 5.68 | 5.57 | 5.39 |
| 8 | 5.51 | 5.72 | 5.91 | 6.09 | 6.21 | 6.27 | 6.27 | 6.30 | 6.67 | 7.21 | 6.99 | 6.90 | 6.77 | 6.56 |
| 9 | 6.10 | 6.39 | 6.66 | 6.90 | 7.04 | 7.15 | 7.21 | 7.29 | 7.74 | 8.40 | 8.22 | 8.14 | 8.01 | 7.78 |
| 10 | 6.65 | 7.03 | 7.34 | 7.65 | 7.87 | 8.02 | 8.11 | 8.21 | 8.72 | 9.48 | 9.28 | 9.20 | 9.07 | 8.85 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 10.509 | 9.284 |
| SC2 | 0 | 8 | 7.174 | 6.295 |
| SC3 | -18 | 7 | 5.948 | 5.212 |
| SC4 | -25 | 6 | 4.759 | 4.186 |
| SC5 | -34 | 6 | 4.595 | 4.089 |
| A | 1237 mm |
|---|---|
| B | 590 mm |
| C | 685 mm |
| F | 395 mm |
| E | 885 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 1237 mm |
|---|---|
| Width | 590 mm |
| Height | 685 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.