EA-150AC7-C09 C
8.37 kW
Defrost: None
Product code: EA-430AE10-C05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,428 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 30.5 m² |
| Inner volume | 13.9 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 59 kg |
| Quantity | 4 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 46.0 dB(A) |
|---|---|
| Sound power | 68.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EA-430AE10-C05 C | None |
|---|---|
| EA-430AE10-C05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.62 | 3.60 | 3.59 | 3.60 | 3.58 | 3.55 | 3.50 | 3.57 | 3.79 | 4.10 | 4.00 | 3.97 | 3.92 | 3.86 |
| 5 | 4.61 | 4.64 | 4.68 | 4.73 | 4.73 | 4.70 | 4.65 | 4.70 | 4.99 | 5.40 | 5.23 | 5.18 | 5.10 | 4.98 |
| 6 | 5.58 | 5.67 | 5.78 | 5.87 | 5.91 | 5.90 | 5.85 | 5.90 | 6.25 | 6.76 | 6.54 | 6.46 | 6.33 | 6.13 |
| 7 | 6.53 | 6.71 | 6.86 | 7.02 | 7.10 | 7.13 | 7.09 | 7.14 | 7.56 | 8.18 | 7.91 | 7.80 | 7.63 | 7.36 |
| 8 | 7.40 | 7.68 | 7.93 | 8.17 | 8.31 | 8.35 | 8.33 | 8.40 | 8.90 | 9.62 | 9.32 | 9.19 | 8.99 | 8.66 |
| 9 | 8.21 | 8.58 | 8.93 | 9.24 | 9.45 | 9.58 | 9.59 | 9.67 | 10.25 | 11.07 | 10.75 | 10.60 | 10.37 | 9.98 |
| 10 | 8.92 | 9.41 | 9.86 | 10.25 | 10.49 | 10.66 | 10.73 | 10.87 | 11.53 | 12.50 | 12.19 | 12.02 | 11.77 | 11.32 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 12.188 |
| SC2 | 0 | 8 | 8.400 |
| SC3 | -18 | 7 | 7.058 |
| SC4 | -25 | 6 | 5.775 |
| SC5 | -34 | 6 | 5.603 |
| A | 2107 mm |
|---|---|
| B | 567 mm |
| C | 445 mm |
| F | 395 mm |
| E1 | 455 mm |
| E2 | 437.5 mm |
| E | 1785 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 2107 mm |
|---|---|
| Width | 567 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.