EA-163GG10-C19 C
22.77 kW
Defrost: None
Product code: EA-440AG10-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 10,995 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 71.7 m² |
| Inner volume | 32.8 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 151 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 640 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 86.0 dB(A) |
| Energy class | B |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø42 |
| EA-440AG10-C01 C | None |
|---|---|
| EA-440AG10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 9.69 | 9.70 | 9.73 | 9.76 | 9.72 | 9.62 | 9.46 | 9.66 | 10.28 | 11.12 | 10.83 | 10.74 | 10.61 | 10.45 |
| 5 | 12.30 | 12.48 | 12.66 | 12.82 | 12.85 | 12.78 | 12.61 | 12.78 | 13.56 | 14.66 | 14.18 | 14.01 | 13.77 | 13.43 |
| 6 | 14.88 | 15.26 | 15.57 | 15.90 | 16.05 | 16.04 | 15.90 | 16.05 | 17.00 | 18.38 | 17.74 | 17.50 | 17.13 | 16.54 |
| 7 | 17.22 | 17.88 | 18.48 | 19.00 | 19.28 | 19.34 | 19.25 | 19.41 | 20.55 | 22.23 | 21.48 | 21.17 | 20.70 | 19.93 |
| 8 | 19.37 | 20.28 | 21.13 | 21.88 | 22.37 | 22.60 | 22.61 | 22.77 | 24.12 | 26.09 | 25.27 | 24.91 | 24.35 | 23.41 |
| 9 | 21.28 | 22.49 | 23.60 | 24.58 | 25.10 | 25.48 | 25.61 | 25.94 | 27.52 | 29.82 | 29.04 | 28.67 | 28.07 | 26.97 |
| 10 | 23.04 | 24.57 | 25.84 | 27.04 | 27.89 | 28.40 | 28.62 | 29.02 | 30.79 | 33.36 | 32.52 | 32.11 | 31.47 | 30.35 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 32.515 |
| SC2 | 0 | 8 | 22.769 |
| SC3 | -18 | 7 | 19.136 |
| SC4 | -25 | 6 | 15.573 |
| SC5 | -34 | 6 | 14.978 |
| A | 2567 mm |
|---|---|
| B | 686 mm |
| C | 605 mm |
| F | 495 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 2235 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø42 |
| Length | 2567 mm |
|---|---|
| Width | 686 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.