EA-250AC7-C10 C
17.02 kW
Defrost: None
Product code: EA-535AC7-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 12,270 m³/h |
|---|---|
| Air throw | 13 m |
| External surface | 47.7 m² |
| Inner volume | 16.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 102 kg |
| Quantity | 5 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 825 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 55.0 dB(A) |
|---|---|
| Sound power | 77.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| EA-535AC7-C01 C | None |
|---|---|
| EA-535AC7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.92 | 6.94 | 6.96 | 6.98 | 6.94 | 6.86 | 6.75 | 6.81 | 7.21 | 7.76 | 7.51 | 7.42 | 7.29 | 7.10 |
| 5 | 8.94 | 9.13 | 9.29 | 9.40 | 9.44 | 9.39 | 9.28 | 9.36 | 9.92 | 10.70 | 10.36 | 10.25 | 10.08 | 9.84 |
| 6 | 10.79 | 11.17 | 11.53 | 11.85 | 12.03 | 12.07 | 11.99 | 12.09 | 12.81 | 13.84 | 13.41 | 13.25 | 13.00 | 12.63 |
| 7 | 12.34 | 12.93 | 13.46 | 13.88 | 14.19 | 14.38 | 14.45 | 14.65 | 15.56 | 16.90 | 16.49 | 16.34 | 16.10 | 15.63 |
| 8 | 13.78 | 14.51 | 15.24 | 15.89 | 16.35 | 16.63 | 16.77 | 17.00 | 18.06 | 19.63 | 19.17 | 18.98 | 18.70 | 18.22 |
| 9 | 15.10 | 16.05 | 17.01 | 17.86 | 18.47 | 18.87 | 19.09 | 19.37 | 20.59 | 22.38 | 21.89 | 21.67 | 21.34 | 20.78 |
| 10 | 16.21 | 17.49 | 18.69 | 19.77 | 20.54 | 21.08 | 21.39 | 21.75 | 23.13 | 25.15 | 24.63 | 24.39 | 24.02 | 23.38 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.631 |
| SC2 | 0 | 8 | 16.999 |
| SC3 | -18 | 7 | 14.019 |
| SC4 | -25 | 6 | 11.530 |
| SC5 | -34 | 6 | 10.884 |
| A | 2857 mm |
|---|---|
| B | 523 mm |
| C | 525 mm |
| F | 345 mm |
| E1 | 517.5 mm |
| E2 | 500 mm |
| E | 2535 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2857 mm |
|---|---|
| Width | 523 mm |
| Height | 525 mm |