EA-463GD10-C08 C
68.15 kW
Defrost: None
Product code: EA-563ED4-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 39,294 m³/h |
|---|---|
| Air throw | 24 m |
| External surface | 417.7 m² |
| Inner volume | 84.5 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 476 kg |
| Quantity | 5 |
|---|---|
| Diameter | 630 mm |
| Speed | 860 rpm |
| Power | 3,000 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 58.0 dB(A) |
|---|---|
| Sound power | 81.5 dB(A) |
| Energy class | D |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EA-563ED4-C01 C | None |
|---|---|
| EA-563ED4-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 29.88 | 29.55 | 29.42 | 29.42 | 29.30 | 29.10 | 28.85 | 29.37 | 31.23 | 33.85 | 33.16 | 32.89 | 32.50 | 31.93 |
| 5 | 38.38 | 38.31 | 38.38 | 38.45 | 38.36 | 38.10 | 37.71 | 38.13 | 40.47 | 43.79 | 42.69 | 42.31 | 41.79 | 41.02 |
| 6 | 46.66 | 47.14 | 47.61 | 48.05 | 48.08 | 47.81 | 47.30 | 47.62 | 50.46 | 54.52 | 52.90 | 52.32 | 51.51 | 50.28 |
| 7 | 54.60 | 55.60 | 56.69 | 57.61 | 57.96 | 57.85 | 57.38 | 57.62 | 61.00 | 65.89 | 63.80 | 63.02 | 61.88 | 60.09 |
| 8 | 61.46 | 63.39 | 65.20 | 66.82 | 67.78 | 68.21 | 67.84 | 68.08 | 72.06 | 77.86 | 75.36 | 74.38 | 72.94 | 70.63 |
| 9 | 67.83 | 70.59 | 73.09 | 75.29 | 76.64 | 77.28 | 77.41 | 78.02 | 82.72 | 89.62 | 87.27 | 86.16 | 84.43 | 81.60 |
| 10 | 73.77 | 77.46 | 80.77 | 83.64 | 85.40 | 86.39 | 86.68 | 87.39 | 92.66 | 100.35 | 97.75 | 96.62 | 94.93 | 92.11 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 97.745 |
| SC2 | 0 | 8 | 68.083 |
| SC3 | -18 | 7 | 57.814 |
| SC4 | -25 | 6 | 47.611 |
| SC5 | -34 | 6 | 46.827 |
| A | 4415 mm |
|---|---|
| B | 950 mm |
| C | 1190 mm |
| F | 910 mm |
| E1 | 818 mm |
| E2 | 800 mm |
| E | 4035 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 4415 mm |
|---|---|
| Width | 1000 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.