EA-463GG10-C13 C
107.11 kW
Defrost: None
Product code: EA-563FG10-C08 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 72,025 m³/h |
|---|---|
| Air throw | 43 m |
| External surface | 406.9 m² |
| Inner volume | 166.7 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 715 kg |
| Quantity | 5 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 9,500 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 75.0 dB(A) |
|---|---|
| Sound power | 99.0 dB(A) |
| Energy class | D |
| Inlet | Ø54 |
|---|---|
| Outlet | Ø66,7 |
| EA-563FG10-C08 C | None |
|---|---|
| EA-563FG10-C08 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 46.03 | 45.50 | 45.15 | 44.91 | 44.43 | 43.80 | 43.06 | 43.46 | 45.99 | 49.49 | 47.97 | 47.40 | 46.60 | 45.39 |
| 5 | 59.49 | 59.58 | 59.74 | 59.78 | 59.47 | 58.82 | 57.93 | 58.20 | 61.60 | 66.38 | 64.26 | 63.52 | 62.48 | 60.87 |
| 6 | 72.24 | 73.39 | 74.40 | 75.22 | 75.30 | 74.82 | 73.85 | 74.04 | 78.32 | 84.38 | 81.51 | 80.46 | 78.94 | 76.58 |
| 7 | 84.24 | 86.71 | 88.47 | 90.24 | 91.01 | 90.97 | 90.27 | 90.48 | 95.70 | 103.22 | 99.68 | 98.33 | 96.34 | 93.15 |
| 8 | 94.77 | 98.46 | 101.82 | 104.80 | 106.63 | 107.34 | 106.99 | 107.36 | 113.62 | 122.73 | 118.72 | 117.12 | 114.73 | 110.82 |
| 9 | 104.31 | 109.37 | 113.97 | 117.99 | 120.56 | 122.00 | 122.49 | 123.48 | 130.97 | 141.91 | 138.12 | 136.29 | 133.55 | 129.01 |
| 10 | 113.11 | 119.72 | 125.69 | 130.87 | 134.25 | 136.29 | 137.19 | 138.49 | 146.92 | 159.22 | 155.24 | 153.50 | 150.89 | 146.46 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 39.99 | 39.33 | 38.95 | 38.73 | 38.35 | 37.86 | 37.30 | 37.74 | 40.04 | 43.25 | 42.11 | 41.66 | 41.04 | 40.08 |
| 5 | 51.62 | 51.16 | 51.09 | 51.10 | 50.79 | 50.24 | 49.51 | 49.80 | 52.75 | 56.91 | 55.17 | 54.57 | 53.72 | 52.49 |
| 6 | 62.86 | 63.20 | 63.61 | 64.02 | 63.84 | 63.36 | 62.56 | 62.73 | 66.36 | 71.55 | 69.17 | 68.30 | 67.04 | 65.11 |
| 7 | 73.64 | 74.87 | 76.02 | 77.02 | 77.29 | 76.98 | 76.20 | 76.27 | 80.65 | 86.98 | 83.99 | 82.85 | 81.16 | 78.45 |
| 8 | 83.81 | 86.13 | 87.89 | 89.67 | 90.51 | 90.57 | 89.99 | 90.12 | 95.30 | 102.85 | 99.34 | 97.95 | 95.89 | 92.54 |
| 9 | 93.28 | 96.32 | 99.43 | 102.23 | 103.73 | 104.25 | 103.93 | 104.25 | 110.29 | 119.05 | 115.24 | 113.62 | 111.22 | 107.22 |
| 10 | 101.22 | 105.76 | 109.91 | 113.58 | 115.81 | 117.09 | 117.47 | 118.38 | 125.42 | 135.46 | 131.34 | 129.53 | 126.81 | 122.23 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 155.243 | 131.335 |
| SC2 | 0 | 8 | 107.363 | 90.117 |
| SC3 | -18 | 7 | 90.655 | 77.207 |
| SC4 | -25 | 6 | 74.397 | 63.613 |
| SC5 | -34 | 6 | 72.594 | 63.024 |
| A | 5415 mm |
|---|---|
| B | 1100 mm |
| C | 1190 mm |
| F | 1060 mm |
| G | 1135 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 5035 mm |
| D IN | 1 x Ø54 |
| D OUT | 1 x Ø66,7 |
| Length | 5415 mm |
|---|---|
| Width | 1100 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.