EB-335AE4-B01 C
17.18 kW
Defrost: None
Product code: EB-245AE4-B01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 8,381 m³/h |
|---|---|
| Air throw | 15 m |
| External surface | 57.5 m² |
| Inner volume | 10.4 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 80 kg |
| Quantity | 2 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,310 rpm |
| Power | 980 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 56.0 dB(A) |
|---|---|
| Sound power | 78.0 dB(A) |
| Energy class | D |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø35 |
| EB-245AE4-B01 C | None |
|---|---|
| EB-245AE4-B01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.41 | 7.37 | 7.36 | 7.35 | 7.30 | 7.20 | 7.08 | 7.27 | 7.74 | 8.38 | 8.18 | 8.13 | 8.03 | 7.86 |
| 5 | 9.55 | 9.64 | 9.73 | 9.80 | 9.77 | 9.67 | 9.49 | 9.68 | 10.27 | 11.10 | 10.75 | 10.64 | 10.49 | 10.28 |
| 6 | 11.53 | 11.78 | 12.03 | 12.26 | 12.37 | 12.29 | 12.10 | 12.25 | 12.97 | 14.01 | 13.50 | 13.31 | 13.04 | 12.62 |
| 7 | 13.28 | 13.69 | 14.08 | 14.42 | 14.61 | 14.65 | 14.57 | 14.75 | 15.64 | 16.95 | 16.42 | 16.21 | 15.83 | 15.23 |
| 8 | 15.04 | 15.62 | 16.16 | 16.63 | 16.86 | 16.96 | 16.88 | 17.06 | 18.08 | 19.57 | 18.95 | 18.69 | 18.30 | 17.63 |
| 9 | 16.60 | 17.41 | 18.14 | 18.77 | 19.13 | 19.28 | 19.22 | 19.42 | 20.57 | 22.24 | 21.54 | 21.23 | 20.74 | 19.92 |
| 10 | 18.06 | 19.12 | 20.07 | 20.88 | 21.37 | 21.61 | 21.60 | 21.78 | 23.06 | 24.92 | 24.15 | 23.79 | 23.22 | 22.26 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.153 |
| SC2 | 0 | 8 | 17.061 |
| SC3 | -18 | 7 | 14.515 |
| SC4 | -25 | 6 | 12.026 |
| SC5 | -34 | 6 | 11.596 |
| A | 1667 mm |
|---|---|
| B | 650 mm |
| C | 617 mm |
| F | 445 mm |
| E1 | 668 mm |
| E | 1335 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø35 |
| Length | 1667 mm |
|---|---|
| Width | 650 mm |
| Height | 617 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.