EB-340AC6-B01 C
15.34 kW
Defrost: None
Product code: EB-335AE6-B01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 7,391 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 51.2 m² |
| Inner volume | 12.4 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 82 kg |
| Quantity | 3 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 495 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | B |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| EB-335AE6-B01 C | None |
|---|---|
| EB-335AE6-B01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.63 | 6.68 | 6.74 | 6.80 | 6.80 | 6.77 | 6.70 | 6.79 | 7.21 | 7.80 | 7.60 | 7.53 | 7.42 | 7.29 |
| 5 | 8.35 | 8.54 | 8.72 | 8.88 | 8.95 | 8.96 | 8.89 | 8.98 | 9.52 | 10.30 | 10.00 | 9.89 | 9.73 | 9.48 |
| 6 | 9.96 | 10.29 | 10.62 | 10.92 | 11.11 | 11.20 | 11.17 | 11.27 | 11.95 | 12.94 | 12.55 | 12.40 | 12.17 | 11.80 |
| 7 | 11.37 | 11.87 | 12.34 | 12.76 | 13.05 | 13.21 | 13.27 | 13.42 | 14.25 | 15.47 | 15.08 | 14.92 | 14.67 | 14.23 |
| 8 | 12.79 | 13.46 | 14.07 | 14.63 | 14.97 | 15.20 | 15.30 | 15.49 | 16.44 | 17.84 | 17.40 | 17.21 | 16.91 | 16.41 |
| 9 | 14.03 | 14.90 | 15.70 | 16.41 | 16.90 | 17.21 | 17.34 | 17.57 | 18.66 | 20.24 | 19.76 | 19.53 | 19.19 | 18.60 |
| 10 | 15.16 | 16.25 | 17.26 | 18.14 | 18.77 | 19.19 | 19.41 | 19.63 | 20.85 | 22.60 | 22.10 | 21.85 | 21.47 | 20.80 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 22.097 |
| SC2 | 0 | 8 | 15.490 |
| SC3 | -18 | 7 | 12.891 |
| SC4 | -25 | 6 | 10.618 |
| SC5 | -34 | 6 | 10.041 |
| A | 2157 mm |
|---|---|
| B | 520 mm |
| C | 553 mm |
| F | 345 mm |
| E1 | 618 mm |
| E2 | 600 mm |
| E | 1835 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2157 mm |
|---|---|
| Width | 520 mm |
| Height | 553 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.