ED-430AC7-C25 C
8.46 kW
Defrost: None
Product code: ED-145AE7-C23 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,546 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 30.5 m² |
| Inner volume | 10.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 67 kg |
| Quantity | 1 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,300 rpm |
| Power | 350 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 58.0 dB(A) |
|---|---|
| Sound power | 80.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| ED-145AE7-C23 C | None |
|---|---|
| ED-145AE7-C23 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.60 | 3.54 | 3.51 | 3.49 | 3.46 | 3.42 | 3.37 | 3.40 | 3.60 | 3.89 | 3.79 | 3.75 | 3.70 | 3.62 |
| 5 | 4.67 | 4.65 | 4.65 | 4.66 | 4.63 | 4.59 | 4.53 | 4.54 | 4.81 | 5.19 | 5.03 | 4.98 | 4.91 | 4.80 |
| 6 | 5.72 | 5.77 | 5.83 | 5.88 | 5.88 | 5.85 | 5.78 | 5.79 | 6.13 | 6.61 | 6.39 | 6.31 | 6.20 | 6.03 |
| 7 | 6.77 | 6.90 | 7.02 | 7.12 | 7.17 | 7.16 | 7.11 | 7.11 | 7.52 | 8.12 | 7.85 | 7.75 | 7.60 | 7.35 |
| 8 | 7.73 | 7.97 | 8.19 | 8.38 | 8.48 | 8.50 | 8.46 | 8.48 | 8.97 | 9.69 | 9.39 | 9.26 | 9.08 | 8.77 |
| 9 | 8.59 | 8.93 | 9.24 | 9.52 | 9.70 | 9.81 | 9.84 | 9.87 | 10.44 | 11.29 | 10.96 | 10.81 | 10.60 | 10.23 |
| 10 | 9.37 | 9.82 | 10.23 | 10.60 | 10.80 | 10.96 | 11.03 | 11.13 | 11.81 | 12.80 | 12.51 | 12.37 | 12.16 | 11.73 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 12.505 |
| SC2 | 0 | 8 | 8.482 |
| SC3 | -18 | 7 | 7.146 |
| SC4 | -25 | 6 | 5.827 |
| SC5 | -34 | 6 | 5.741 |
| A | 1148 mm |
|---|---|
| B | 1210 mm |
| C | 365 mm |
| F | 1135 mm |
| G | 441 mm |
| E1 | 835 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 1148 mm |
|---|---|
| Width | 1210 mm |
| Height | 441 mm |