ED-435AE4-C21 C
22.11 kW
Defrost: None
Product code: ED-245AE4-C23 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 8,508 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 97.4 m² |
| Inner volume | 21.4 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 125 kg |
| Quantity | 2 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,300 rpm |
| Power | 700 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø42 |
| ED-245AE4-C23 C | None |
|---|---|
| ED-245AE4-C23 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 9.63 | 9.64 | 9.68 | 9.73 | 9.72 | 9.66 | 9.56 | 9.72 | 10.33 | 11.20 | 10.93 | 10.84 | 10.72 | 10.54 |
| 5 | 12.14 | 12.30 | 12.47 | 12.62 | 12.67 | 12.62 | 12.49 | 12.62 | 13.39 | 14.49 | 14.06 | 13.90 | 13.69 | 13.36 |
| 6 | 14.61 | 14.97 | 15.30 | 15.59 | 15.70 | 15.70 | 15.58 | 15.68 | 16.61 | 17.96 | 17.38 | 17.15 | 16.82 | 16.30 |
| 7 | 16.82 | 17.40 | 17.95 | 18.44 | 18.73 | 18.85 | 18.75 | 18.85 | 19.96 | 21.55 | 20.86 | 20.57 | 20.15 | 19.45 |
| 8 | 18.79 | 19.63 | 20.39 | 20.98 | 21.41 | 21.62 | 21.66 | 21.85 | 23.16 | 25.08 | 24.40 | 24.09 | 23.57 | 22.71 |
| 9 | 20.62 | 21.74 | 22.64 | 23.52 | 24.10 | 24.41 | 24.51 | 24.73 | 26.22 | 28.38 | 27.62 | 27.27 | 26.75 | 25.83 |
| 10 | 22.31 | 23.61 | 24.89 | 26.00 | 26.75 | 27.19 | 27.36 | 27.63 | 29.29 | 31.71 | 30.88 | 30.49 | 29.88 | 28.84 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 30.878 |
| SC2 | 0 | 8 | 21.850 |
| SC3 | -18 | 7 | 18.576 |
| SC4 | -25 | 6 | 15.302 |
| SC5 | -34 | 6 | 14.708 |
| A | 1948 mm |
|---|---|
| B | 1210 mm |
| C | 365 mm |
| F | 1135 mm |
| G | 441 mm |
| E1 | 1635 mm |
| E2 | 818 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø42 |
| Length | 1948 mm |
|---|---|
| Width | 1210 mm |
| Height | 441 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.