ED-435AC4-C21 C
19.22 kW
Defrost: None
Product code: ED-340AC4-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 9,894 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 73.0 m² |
| Inner volume | 16.2 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 120 kg |
| Quantity | 3 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 63.0 dB(A) |
|---|---|
| Sound power | 85.0 dB(A) |
| Energy class | C |
| Inlet | Ø28 |
|---|---|
| Outlet | Ø35 |
| ED-340AC4-C21 C | None |
|---|---|
| ED-340AC4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.97 | 8.12 | 8.25 | 8.35 | 8.38 | 8.35 | 8.27 | 8.37 | 8.88 | 9.61 | 9.37 | 9.29 | 9.17 | 8.98 |
| 5 | 10.09 | 10.45 | 10.77 | 11.02 | 11.15 | 11.16 | 11.10 | 11.20 | 11.88 | 12.84 | 12.48 | 12.35 | 12.16 | 11.89 |
| 6 | 11.88 | 12.44 | 12.96 | 13.40 | 13.63 | 13.81 | 13.88 | 14.06 | 14.94 | 16.22 | 15.83 | 15.66 | 15.40 | 14.99 |
| 7 | 13.47 | 14.17 | 14.92 | 15.55 | 15.99 | 16.26 | 16.40 | 16.61 | 17.65 | 19.17 | 18.74 | 18.57 | 18.31 | 17.87 |
| 8 | 14.92 | 15.89 | 16.86 | 17.71 | 18.32 | 18.71 | 18.93 | 19.19 | 20.40 | 22.17 | 21.69 | 21.48 | 21.17 | 20.64 |
| 9 | ≈ 16.14 | 17.47 | 18.70 | 19.80 | 20.59 | 21.13 | 21.45 | 21.79 | 23.17 | 25.19 | 24.67 | 24.44 | 24.08 | 23.46 |
| 10 | ≈ 17.31 | 18.92 | 20.44 | 21.80 | 22.81 | 23.52 | 23.96 | 24.39 | 25.95 | 28.22 | 27.68 | 27.43 | 27.03 | 26.32 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 27.684 |
| SC2 | 0 | 8 | 19.192 |
| SC3 | -18 | 7 | 15.751 |
| SC4 | -25 | 6 | 12.955 |
| SC5 | -34 | 6 | 12.016 |
| A | 2148 mm |
|---|---|
| B | 1210 mm |
| C | 365 mm |
| F | 1135 mm |
| G | 467 mm |
| E1 | 1835 mm |
| E2 | 618 mm |
| E3 | 600 mm |
| D IN | 1 x Ø28 |
| D OUT | 1 x Ø35 |
| Length | 2148 mm |
|---|---|
| Width | 1210 mm |
| Height | 467 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.