EK-K-b-663BE10-B29 C
100.45 kW
Defrost: None
Product code: EK-K-s-663BE10-B08 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 89,222 m³/h |
|---|---|
| External surface | 329.6 m² |
| Inner volume | 141.3 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 795 kg |
| Quantity | 6 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 11,400 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 76.0 dB(A) |
|---|---|
| Sound power | 100.0 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EK-K-s-663BE10-B08 C | None |
|---|---|
| EK-K-s-663BE10-B08 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 44.36 | 42.67 | 41.56 | 40.84 | 40.12 | 39.42 | 38.77 | 38.85 | 41.01 | 44.17 | 42.91 | 42.46 | 41.82 | 40.89 |
| 5 | 53.23 | 51.61 | 50.51 | 55.27 | 54.30 | 53.27 | 52.23 | 52.23 | 55.21 | 59.40 | 57.55 | 56.87 | 55.90 | 54.45 |
| 6 | 67.11 | 65.65 | 64.58 | 70.99 | 69.94 | 68.69 | 67.31 | 67.11 | 70.85 | 76.14 | 73.50 | 72.57 | 71.26 | 69.32 |
| 7 | 80.87 | 79.88 | 79.27 | 87.61 | 86.59 | 85.27 | 83.68 | 83.30 | 87.91 | 94.41 | 90.91 | 89.65 | 87.85 | 85.15 |
| 8 | 94.32 | 94.07 | 94.07 | 104.61 | 103.94 | 102.70 | 100.98 | 100.45 | 105.98 | 113.87 | 109.51 | 107.89 | 105.54 | 101.91 |
| 9 | 119.16 | 120.00 | 120.62 | 121.49 | 121.35 | 120.41 | 118.83 | 118.25 | 124.78 | 134.19 | 129.07 | 127.08 | 124.21 | 119.64 |
| 10 | 131.92 | 133.93 | 136.11 | 138.30 | 138.95 | 138.44 | 137.08 | 136.55 | 144.15 | 155.14 | 149.47 | 147.19 | 143.85 | 138.46 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 38.93 | 37.50 | 36.63 | 36.11 | 35.59 | 35.08 | 34.60 | 34.96 | 36.96 | 39.89 | 38.87 | 38.50 | 37.98 | 37.21 |
| 5 | 46.33 | 44.88 | 43.96 | 48.20 | 47.48 | 46.71 | 45.92 | 46.14 | 48.86 | 52.69 | 51.20 | 50.69 | 49.98 | 48.92 |
| 6 | 58.05 | 56.65 | 55.75 | 61.32 | 60.48 | 59.51 | 58.44 | 58.45 | 61.80 | 66.54 | 64.37 | 63.62 | 62.57 | 61.02 |
| 7 | 70.04 | 68.83 | 68.03 | 75.13 | 74.31 | 73.23 | 71.95 | 71.75 | 75.78 | 81.51 | 78.62 | 77.58 | 76.10 | 73.87 |
| 8 | 81.80 | 81.01 | 80.65 | 89.44 | 88.70 | 87.63 | 86.22 | 85.84 | 90.60 | 97.44 | 93.83 | 92.48 | 90.55 | 87.54 |
| 9 | 103.62 | 103.43 | 103.61 | 103.92 | 103.50 | 102.52 | 101.04 | 100.54 | 106.10 | 114.16 | 109.88 | 108.21 | 105.80 | 101.99 |
| 10 | 115.90 | 116.63 | 117.53 | 118.46 | 118.28 | 117.54 | 116.19 | 115.65 | 122.06 | 131.30 | 126.50 | 124.54 | 121.70 | 117.12 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 149.473 | 126.499 |
| SC2 | 0 | 8 | 100.451 | 85.843 |
| SC3 | -18 | 7 | 87.277 | 74.839 |
| SC4 | -25 | 6 | 64.577 | 55.754 |
| SC5 | -34 | 6 | 66.880 | 57.813 |
| A | 3460 mm |
|---|---|
| B | 1050 mm |
| C | 1935 mm |
| F | 840 mm |
| G | 3035 mm |
| E | 2050 mm |
| G1 | 1035 mm |
| G2 | 1000 mm |
| D IN | 2 x Ø42 |
| D OUT | 2 x Ø66,7 |
| Length | 3460 mm |
|---|---|
| Width | 1050 mm |
| Height | 2050 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.