Skip to Content

Blast freezer EK-S-250AG10-B10 C

Blast freezer EK-S-250AG10-B10 C
Illustrative photo

Producer: Karyer · Line: EK-S (Blast Freezers)

Product code: EK-S-250AG10-B10 C

Cooling capacity i
26.18 kW
Air flow
14,724 m³/h
Fin spacing
10.0 mm
Fans
2 × ⌀500 mm

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Data

Evaporator
Air flow 14,724 m³/h
External surface 117.2 m²
Inner volume 49.7 dm³
Fin spacing 10.0 mm
Fin materialAluminium
Net weight 379 kg
Fans
Quantity 2
Diameter 500 mm
Speed 1,360 rpm
Power 1,380 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 60.0 dB(A)
Sound power 83.1 dB(A)
Energy class C
Connections
Inlet Ø28
Outlet Ø54
Defrost
EK-S-250AG10-B10 C None
EK-S-250AG10-B10 C ED Electric

Performance

TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.

R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)

High speed (Δ)
26.183 kW
Low speed (Y)
22.444 kW

Capacity matrix [kW]

R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.

High speed (Δ)

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 12.23 11.84 11.62 11.50 11.38 11.26 11.14 11.22 11.90 12.87 12.57 12.47 12.30 12.06
5 14.31 13.92 13.70 15.09 14.93 14.76 14.57 14.60 15.46 16.70 16.23 16.07 15.85 15.51
6 17.69 17.32 17.12 18.91 18.73 18.52 18.27 18.26 19.30 20.82 20.17 19.94 19.61 19.11
7 21.14 20.78 20.64 22.87 22.72 22.49 22.20 22.13 23.38 25.20 24.37 24.06 23.62 22.93
8 24.51 24.30 24.24 26.93 26.82 26.60 26.29 26.18 27.66 29.80 28.79 28.40 27.83 26.94
9 30.90 30.83 30.91 31.06 31.02 30.80 30.49 30.38 32.08 34.55 33.39 32.92 32.24 31.14
10 34.44 34.61 34.88 35.19 35.22 35.09 34.79 34.67 36.62 39.44 38.14 37.59 36.80 35.49

Low speed (Y)

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 10.69 10.37 10.19 10.12 10.04 9.95 9.85 9.97 10.59 11.47 11.22 11.13 11.02 10.85
5 12.43 12.09 11.91 13.14 13.03 12.90 12.75 12.82 13.59 14.69 14.30 14.17 13.98 13.70
6 15.31 14.97 14.78 16.34 16.21 16.04 15.85 15.87 16.80 18.13 17.59 17.40 17.12 16.70
7 18.23 17.90 17.75 19.66 19.53 19.35 19.11 19.09 20.18 21.77 21.07 20.81 20.43 19.84
8 21.17 20.86 20.77 23.07 22.96 22.77 22.51 22.44 23.71 25.57 24.72 24.39 23.90 23.14
9 26.72 26.51 26.48 26.53 26.46 26.27 25.99 25.91 27.37 29.49 28.50 28.10 27.52 26.57
10 29.83 29.77 29.86 30.03 30.00 29.83 29.55 29.47 31.12 33.52 32.41 31.94 31.25 30.12

Standard ratings (EN 328 / Eurovent)

Standard condition Air inlet [°C] TD [K] High speed (Δ) [kW]Low speed (Y) [kW]
SC1 10 10 38.13632.406
SC2 0 8 26.18322.444
SC3 -18 7 22.81919.619
SC4 -25 6 17.11614.784
SC5 -34 6 17.62915.252

Dimensions

Dimension drawing of EK-S-250AG10-B10 C
Dimension drawing
Dimensions as drawn
A 2060 mm
B 1100 mm
C 1930 mm
F 700 mm
G 1665 mm
E 2170 mm
G1 833 mm
G2 800 mm
D IN 1 x Ø28
D OUT 1 x Ø54
Overall [mm]
Length 2060 mm
Width 1100 mm
Height 2170 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.