EK-SR-480BE10-A05 C
109.58 kW
Defrost: None
Product code: EK-SR-491DC10-A03 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 139,262 m³/h |
|---|---|
| External surface | 380.9 m² |
| Inner volume | 157.3 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 1,345 kg |
| Quantity | 4 |
|---|---|
| Diameter | 910 mm |
| Speed | 1,210 rpm |
| Power | 20,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 71.0 dB(A) |
|---|---|
| Sound power | 95.9 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-491DC10-A03 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 45.11 | 44.72 | 44.44 | 44.21 | 43.73 | 43.12 | 42.44 | 42.12 | 44.39 | 47.69 | 46.09 | 45.50 | 44.66 | 43.40 |
| 5 | 52.64 | 53.04 | 53.37 | 59.59 | 59.30 | 58.78 | 58.05 | 57.70 | 60.91 | 65.49 | 63.29 | 62.48 | 61.32 | 59.47 |
| 6 | 63.90 | 65.44 | 66.74 | 75.31 | 75.45 | 75.32 | 74.78 | 74.55 | 78.73 | 84.78 | 82.04 | 81.00 | 79.49 | 77.14 |
| 7 | 74.37 | 76.76 | 79.24 | 90.47 | 91.74 | 92.24 | 92.11 | 92.13 | 97.49 | 105.18 | 102.03 | 100.79 | 98.97 | 96.03 |
| 8 | 82.81 | 86.74 | 90.30 | 103.83 | 106.16 | 107.64 | 108.45 | 109.27 | 115.99 | 125.78 | 122.71 | 121.34 | 119.29 | 115.94 |
| 9 | 100.99 | 106.87 | 112.17 | 116.83 | 120.08 | 122.19 | 123.47 | 124.61 | 132.34 | 143.65 | 140.63 | 139.39 | 137.53 | 134.43 |
| 10 | 109.23 | 116.73 | 123.53 | 129.51 | 133.76 | 136.65 | 138.48 | 140.01 | 148.78 | 161.64 | 158.43 | 157.08 | 155.04 | 151.60 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 38.88 | 38.29 | 37.92 | 37.70 | 37.32 | 36.87 | 36.38 | 36.32 | 38.34 | 41.27 | 40.03 | 39.57 | 38.92 | 37.94 |
| 5 | 45.39 | 45.25 | 45.15 | 50.24 | 50.00 | 49.54 | 48.96 | 48.81 | 51.59 | 55.55 | 53.83 | 53.20 | 52.31 | 50.94 |
| 6 | 55.35 | 55.94 | 56.51 | 63.37 | 63.42 | 63.07 | 62.53 | 62.36 | 65.92 | 71.02 | 68.79 | 67.95 | 66.75 | 64.89 |
| 7 | 64.81 | 66.34 | 67.71 | 76.31 | 76.88 | 76.95 | 76.60 | 76.53 | 80.95 | 87.29 | 84.63 | 83.61 | 82.11 | 79.73 |
| 8 | 73.66 | 75.94 | 78.25 | 89.18 | 90.46 | 91.01 | 91.00 | 91.12 | 96.46 | 104.22 | 101.23 | 100.04 | 98.28 | 95.42 |
| 9 | 90.04 | 93.94 | 97.53 | 100.76 | 102.92 | 104.29 | 105.04 | 105.83 | 112.23 | 121.44 | 118.20 | 116.88 | 114.92 | 111.68 |
| 10 | 97.85 | 103.04 | 107.74 | 111.91 | 114.79 | 116.66 | 117.79 | 118.82 | 126.16 | 136.92 | 134.03 | 132.82 | 130.99 | 127.93 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 158.431 | 134.029 |
| SC2 | 0 | 8 | 109.267 | 91.120 |
| SC3 | -18 | 7 | 91.086 | 76.596 |
| SC4 | -25 | 6 | 66.741 | 56.508 |
| SC5 | -34 | 6 | 64.334 | 55.551 |
| A | 5660 mm |
|---|---|
| B | 1360 mm |
| C | 3390 mm |
| F | 1310 mm |
| G | 2370 mm |
| E | 5265 mm |
| H | 1393 mm |
| I | 5690 mm |
| D IN | 2 x Ø35 |
| D OUT | 2 x Ø54 |
| Length | 5660 mm |
|---|---|
| Width | 1393 mm |
| Height | 3390 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.