EA-G-563FD7-A08 C
81.44 kW
Defrost: None
Product code: EA-G-563FC4-A19 C
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Air flow | 58,885 m³/h |
|---|---|
| Air throw | 34 m |
| External surface | 417.7 m² |
| Inner volume | 88.5 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 421 kg |
| Quantity | 5 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 6,250 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 67.0 dB(A) |
|---|---|
| Sound power | 91.0 dB(A) |
| Energy class | E |
| Inlet | 2 1/2" |
|---|---|
| Outlet | 2 1/2" |
| EA-G-563FC4-A19 C | None |
|---|
ΔT (air inlet − fluid inlet) must be within 6–12 K (fluid outlet = inlet + 3 K); air inlet -25…10 °C. Points below the fluid's freezing point are not rated.
ETHYLENE GLYCOL 30% -10 → -7 °C, air inlet 0 °C (ΔT 10 K)
ETHYLENE GLYCOL 30%; rows: ΔT = air inlet − fluid inlet [K], outlet = inlet + 3 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | ≈ 14.88 | ≈ 15.01 | ≈ 29.21 | 32.65 |
| 8 | not rated | not rated | not rated | not rated | ≈ 50.98 | ≈ 53.87 | ≈ 59.01 | 63.17 |
| 10 | not rated | not rated | not rated | not rated | 77.96 | 81.39 | 85.98 | 93.86 |
| 12 | not rated | not rated | not rated | not rated | not rated | 106.65 | 113.42 | 123.15 |
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | ≈ 14.12 | ≈ 14.24 | ≈ 14.31 | ≈ 28.06 |
| 8 | not rated | not rated | not rated | not rated | ≈ 42.33 | ≈ 47.05 | ≈ 52.22 | ≈ 56.35 |
| 10 | not rated | not rated | not rated | not rated | 68.14 | 71.93 | 76.47 | 83.70 |
| 12 | not rated | not rated | not rated | not rated | not rated | 94.35 | 100.82 | 109.65 |
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Fan connection | Cooling capacity [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 81.390 | 25.56 | 125.0 |
| Low speed (Y) | 71.925 | 22.59 | 100.4 |
| A | 5415 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 5035 mm |
| D IN | 2 1/2" |
| D OUT | 2 1/2" |
| Length | 5415 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.