- Catalogue
- Condensers
- KA/KB (General)
KA/KB (General)
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a
- Capacity
- 14.80–1425.75 kW
- Fans
- ⌀500, ⌀630, ⌀800, ⌀910 mm
- Max. working pressure
- 27 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KA/KB = KA = vertical, KB = horizontal industrial condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 50 = Ø500 mm63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter03 = three-phase 400 V 50 Hz, 12-pole AC fan (in this series)04 = fan motor code; supply/poles vary with diameter06 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] i Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| KA/KB-180GC1-B01 C | 77.01 kW | 1 × ⌀800 | 20,558 |
Variants (1) |
| KA/KB-2x250CB5-B10 C | 77.04 kW | 4 × ⌀500 | 29,498 |
Variants (1) |
| KA/KB-2x163BC5-B19 C | 77.11 kW | 2 × ⌀630 | 23,156 |
Variants (1) |
| KA/KB-2x250AB1-B09 C | 77.17 kW | 4 × ⌀500 | 26,302 |
Variants (1) |
| KA/KB-191FC1-B04I C | 77.20 kW | 1 × ⌀910 | 24,455 |
Variants (1) |
| KA/KB-t-263HA1-B01 C | 77.23 kW | 2 × ⌀630 | 20,064 |
Variants (1) |
| KA/KB-t-2x250EA1-B09 C | 77.34 kW | 4 × ⌀500 | 28,941 |
Variants (1) |
| KA/KB-2x250CB5-B01I C | 77.42 kW | 4 × ⌀500 | 29,357 |
Variants (1) |
| KA/KB-2x180AC1-B03 C | 77.48 kW | 2 × ⌀800 | 16,998 |
Variants (1) |
| KA/KB-280AC1-B03 C | 77.51 kW | 2 × ⌀800 | 16,998 |
Variants (1) |
| KA/KB-350BC1-B09 C | 77.57 kW | 3 × ⌀500 | 19,998 |
Variants (1) |
| KA/KB-350CC1-B10 C | 77.67 kW | 3 × ⌀500 | 20,881 |
Variants (1) |
| KA/KB-450CB5-B10 C | 77.77 kW | 4 × ⌀500 | 29,628 |
Variants (1) |
| KA/KB-263BC5-B19 C | 77.79 kW | 2 × ⌀630 | 23,233 |
Variants (1) |
| KA/KB-2x180CB5-B01I C | 77.80 kW | 2 × ⌀800 | 34,078 |
Variants (1) |
| KA/KB-350CC1-B01I C | 77.87 kW | 3 × ⌀500 | 20,790 |
Variants (1) |
| KA/KB-2x250BC5-B04 C | 78.04 kW | 4 × ⌀500 | 19,068 |
Variants (1) |
| KA/KB-450CB5-B01I C | 78.15 kW | 4 × ⌀500 | 29,482 |
Variants (1) |
| KA/KB-450BC5-B04 C | 78.19 kW | 4 × ⌀500 | 19,068 |
Variants (1) |
| KA/KB-2x250AB1-B01I C | 78.35 kW | 4 × ⌀500 | 26,939 |
Variants (1) |
| KA/KB-2x250AB1-B10 C | 78.44 kW | 4 × ⌀500 | 27,078 |
Variants (1) |
| KA/KB-t-191LB5-B04 C | 78.51 kW | 1 × ⌀910 | 27,799 |
Variants (1) |
| KA/KB-280CB5-B01I C | 78.57 kW | 2 × ⌀800 | 34,252 |
Variants (1) |
| KA/KB-450AB1-B10 C | 78.57 kW | 4 × ⌀500 | 27,078 |
Variants (1) |
| KA/KB-2x163FB5-B01 C | 78.69 kW | 2 × ⌀630 | 19,925 |
Variants (1) |
| KA/KB-t-191LB5-B04I C | 78.73 kW | 1 × ⌀910 | 27,922 |
Variants (1) |
| KA/KB-t-280EA1-B01I C | 78.76 kW | 2 × ⌀800 | 34,858 |
Variants (1) |
| KA/KB-450AB1-B09 C | 78.80 kW | 4 × ⌀500 | 26,302 |
Variants (1) |
| KA/KB-263FB5-B01 C | 78.83 kW | 2 × ⌀630 | 19,925 |
Variants (1) |
| KA/KB-263BB1-B08 C | 78.88 kW | 2 × ⌀630 | 29,949 |
Variants (1) |
| KA/KB-550CB5-B04 C | 78.88 kW | 5 × ⌀500 | 25,375 |
Variants (1) |
| KA/KB-350BC1-B01I C | 78.92 kW | 3 × ⌀500 | 20,459 |
Variants (1) |
| KA/KB-350CD5-B09 C | 79.04 kW | 3 × ⌀500 | 19,871 |
Variants (1) |
| KA/KB-2x163BB1-B08 C | 79.10 kW | 2 × ⌀630 | 29,822 |
Variants (1) |
| KA/KB-191CB1-B04 C | 79.12 kW | 1 × ⌀910 | 28,104 |
Variants (1) |
| KA/KB-191FD5-B04 C | 79.18 kW | 1 × ⌀910 | 23,535 |
Variants (1) |
| KA/KB-191CB1-B04I C | 79.33 kW | 1 × ⌀910 | 28,227 |
Variants (1) |
| KA/KB-191FD5-B04I C | 79.37 kW | 1 × ⌀910 | 23,615 |
Variants (1) |
| KA/KB-350BC1-B10 C | 79.37 kW | 3 × ⌀500 | 20,556 |
Variants (1) |
| KA/KB-350CD5-B10 C | 79.46 kW | 3 × ⌀500 | 20,440 |
Variants (1) |
| KA/KB-180FC1-B01 C | 79.48 kW | 1 × ⌀800 | 20,368 |
Variants (1) |
| KA/KB-363BB5-B06I C | 79.53 kW | 3 × ⌀630 | 26,374 |
Variants (1) |
| KA/KB-180JB1-B01 C | 79.56 kW | 1 × ⌀800 | 22,771 |
Variants (1) |
| KA/KB-180GD5-B01 C | 79.59 kW | 1 × ⌀800 | 20,101 |
Variants (1) |
| KA/KB-180JC5-B01I C | 79.74 kW | 1 × ⌀800 | 20,030 |
Variants (1) |
| KA/KB-550AB1-B04 C | 79.75 kW | 5 × ⌀500 | 23,030 |
Variants (1) |
| KA/KB-t-2x250EB1-B04 C | 79.82 kW | 4 × ⌀500 | 19,137 |
Variants (1) |
| KA/KB-t-380EA5-B03 C | 79.93 kW | 3 × ⌀800 | 28,526 |
Variants (1) |
| KA/KB-450AB1-B01I C | 79.97 kW | 4 × ⌀500 | 26,939 |
Variants (1) |
| KA/KB-180GD1-B01I C | 80.06 kW | 1 × ⌀800 | 17,980 |
Variants (1) |
Nominal conditions (EN 327): air inlet 25 °C, condensing temperature 40 °C (ΔT 15 K), gas inlet superheat 26 K, no subcooling, relative humidity 50 %
Downloads
- KA/KB-180GC1-B01 C — product datasheet (PDF)
- KA/KB-2x250CB5-B10 C — product datasheet (PDF)
- KA/KB-2x163BC5-B19 C — product datasheet (PDF)
- KA/KB-2x250AB1-B09 C — product datasheet (PDF)
- KA/KB-191FC1-B04I C — product datasheet (PDF)
- KA/KB-t-263HA1-B01 C — product datasheet (PDF)
- KA/KB-t-2x250EA1-B09 C — product datasheet (PDF)
- KA/KB-2x250CB5-B01I C — product datasheet (PDF)
- KA/KB-2x180AC1-B03 C — product datasheet (PDF)
- KA/KB-280AC1-B03 C — product datasheet (PDF)
- KA/KB-350BC1-B09 C — product datasheet (PDF)
- KA/KB-350CC1-B10 C — product datasheet (PDF)
- KA/KB-450CB5-B10 C — product datasheet (PDF)
- KA/KB-263BC5-B19 C — product datasheet (PDF)
- KA/KB-2x180CB5-B01I C — product datasheet (PDF)
- KA/KB-350CC1-B01I C — product datasheet (PDF)
- KA/KB-2x250BC5-B04 C — product datasheet (PDF)
- KA/KB-450CB5-B01I C — product datasheet (PDF)
- KA/KB-450BC5-B04 C — product datasheet (PDF)
- KA/KB-2x250AB1-B01I C — product datasheet (PDF)
- KA/KB-2x250AB1-B10 C — product datasheet (PDF)
- KA/KB-t-191LB5-B04 C — product datasheet (PDF)
- KA/KB-280CB5-B01I C — product datasheet (PDF)
- KA/KB-450AB1-B10 C — product datasheet (PDF)
- KA/KB-2x163FB5-B01 C — product datasheet (PDF)
- KA/KB-t-191LB5-B04I C — product datasheet (PDF)
- KA/KB-t-280EA1-B01I C — product datasheet (PDF)
- KA/KB-450AB1-B09 C — product datasheet (PDF)
- KA/KB-263FB5-B01 C — product datasheet (PDF)
- KA/KB-263BB1-B08 C — product datasheet (PDF)
- KA/KB-550CB5-B04 C — product datasheet (PDF)
- KA/KB-350BC1-B01I C — product datasheet (PDF)
- KA/KB-350CD5-B09 C — product datasheet (PDF)
- KA/KB-2x163BB1-B08 C — product datasheet (PDF)
- KA/KB-191CB1-B04 C — product datasheet (PDF)
- KA/KB-191FD5-B04 C — product datasheet (PDF)
- KA/KB-191CB1-B04I C — product datasheet (PDF)
- KA/KB-191FD5-B04I C — product datasheet (PDF)
- KA/KB-350BC1-B10 C — product datasheet (PDF)
- KA/KB-350CD5-B10 C — product datasheet (PDF)
- KA/KB-180FC1-B01 C — product datasheet (PDF)
- KA/KB-363BB5-B06I C — product datasheet (PDF)
- KA/KB-180JB1-B01 C — product datasheet (PDF)
- KA/KB-180GD5-B01 C — product datasheet (PDF)
- KA/KB-180JC5-B01I C — product datasheet (PDF)
- KA/KB-550AB1-B04 C — product datasheet (PDF)
- KA/KB-t-2x250EB1-B04 C — product datasheet (PDF)
- KA/KB-t-380EA5-B03 C — product datasheet (PDF)
- KA/KB-450AB1-B01I C — product datasheet (PDF)
- KA/KB-180GD1-B01I C — product datasheet (PDF)